FabDigitFabDigit

Titanium BT20-R vs BT20-STA

Titanium · BT20 temper comparison

BT20-R and BT20-STA are two conditions of the same titanium grade, BT20: R (as hot-worked / hot-rolled) versus STA (solution treated and aged). The chemistry is identical, so every difference below comes from the condition. BT20-STA is the stronger of the two: yield strength 990 MPa (144 ksi) against 860 MPa (125 ksi) for BT20-R, about 15% more; tensile strength follows at 1,080 MPa (157 ksi) vs 960 MPa (139 ksi). In exchange, BT20-R is the more ductile: elongation 10% versus 8% for BT20-STA, and BT20-STA is harder (36 HRC vs 33 HRC).

BT20-RChoose it when the part is bent, formed or impact-loaded.

BT20-STAChoose it when strength drives the design.

BT20-R vs BT20-STA: properties

BT20-RBT20-STA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

960 MPa139 ksi
1,080 MPa157 ksi

Yield Strength (0.2% offset)

860 MPa125 ksi
990 MPa144 ksi

Elongation at Break

10%
8%

Reduction in Area

28%
22%

Compressive Strength

940 MPa136 ksi
960 MPa139 ksi

Shear Strength

600 MPa87 ksi
610 MPa88.5 ksi

Fatigue Strength (Endurance Limit)

455 MPa66 ksi
520 MPa75.4 ksi

Fracture Toughness (K_IC)

58 MPa·√m52.8 ksi·√in
55 MPa·√m50.1 ksi·√in

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

310 HB
300 HB

Hardness, Rockwell C

33 HRC
36 HRC

Hardness, Vickers

330 HV
355 HV

Same in both: Elastic (Young's) Modulus 118 GPa17.1 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 4.46 g/cm³0.16 lb/in³ · Melting Point (Solidus) 1,590°C2,894 °F · Liquidus Temperature 1,660°C3,020 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

450°C842 °F
480°C896 °F

Same in both: Thermal Conductivity 7.5 W/m·K4.3 BTU/hr·ft·°F · Specific Heat Capacity 540 J/kg·K0.13 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 8.6 µm/m·K4.8 µin/in·°F · Latent Heat of Fusion 365 J/g157 BTU/lb · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.1 % IACS · Electrical Resistivity 1.6×10⁻⁶ Ω·m63 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

84 / 100
85 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

16 / 100
15 / 100

Machinability Rating (AISI 1212 = 100 %)

16%
18%

Weldability

68 / 100
72 / 100

Formability (cold)

25 / 100
30 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 680 MJ/kg292,348 BTU/lb · Embodied Carbon (primary production) 45 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every titanium grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0004.555.5Density (g/cm³)Yield strength (MPa) — log scaleBT20

BT20-R vs BT20-STA — frequently asked

Is BT20-STA stronger than BT20-R?

Yes. BT20-STA has a typical yield strength of 990 MPa (144 ksi) against 860 MPa (125 ksi) for BT20-R — about 15% more. Tensile strength is 1,080 MPa (157 ksi) vs 960 MPa (139 ksi).

Which condition does FabDigit quote by default, R or STA?

M is the default BT20 condition in the FabDigit quote flow (neither R nor STA). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose BT20-R over BT20-STA?

Pick BT20-R when the part is bent, formed or impact-loaded. Pick BT20-STA when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in BT20-R and BT20-STA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.