FabDigitFabDigit

Titanium BT20-DA vs BT20-STA

Titanium · BT20 temper comparison

BT20-DA and BT20-STA are two conditions of the same titanium grade, BT20: DA (duplex (double) annealed) versus STA (solution treated and aged). The chemistry is identical, so every difference below comes from the condition. BT20-STA is the stronger of the two: yield strength 990 MPa (144 ksi) against 900 MPa (131 ksi) for BT20-DA, about 10% more; tensile strength follows at 1,080 MPa (157 ksi) vs 980 MPa (142 ksi). In exchange, BT20-DA is the more ductile: elongation 12% versus 8% for BT20-STA, and BT20-STA is harder (36 HRC vs 33 HRC).

BT20-DAChoose it when the part is bent, formed or impact-loaded.

BT20-STAChoose it when strength drives the design.

BT20-DA vs BT20-STA: properties

BT20-DABT20-STA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

980 MPa142 ksi
1,080 MPa157 ksi

Yield Strength (0.2% offset)

900 MPa131 ksi
990 MPa144 ksi

Elongation at Break

12%
8%

Reduction in Area

33%
22%

Compressive Strength

970 MPa141 ksi
960 MPa139 ksi

Shear Strength

620 MPa89.9 ksi
610 MPa88.5 ksi

Fatigue Strength (Endurance Limit)

490 MPa71.1 ksi
520 MPa75.4 ksi

Fracture Toughness (K_IC)

68 MPa·√m61.9 ksi·√in
55 MPa·√m50.1 ksi·√in

Charpy V-Notch Impact (RT)

38 J28 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

305 HB
300 HB

Hardness, Rockwell C

33 HRC
36 HRC

Hardness, Vickers

325 HV
355 HV

Same in both: Elastic (Young's) Modulus 118 GPa17.1 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 4.46 g/cm³0.16 lb/in³ · Melting Point (Solidus) 1,590°C2,894 °F · Liquidus Temperature 1,660°C3,020 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

520°C968 °F
480°C896 °F

Same in both: Thermal Conductivity 7.5 W/m·K4.3 BTU/hr·ft·°F · Specific Heat Capacity 540 J/kg·K0.13 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 8.6 µm/m·K4.8 µin/in·°F · Latent Heat of Fusion 365 J/g157 BTU/lb · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.1 % IACS · Electrical Resistivity 1.6×10⁻⁶ Ω·m63 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V · Corrosion Resistance 85 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

18 / 100
15 / 100

Weldability

74 / 100
72 / 100

Formability (cold)

32 / 100
30 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 18% · Brazeability / Solderability 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 680 MJ/kg292,348 BTU/lb · Embodied Carbon (primary production) 45 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every titanium grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0004.555.5Density (g/cm³)Yield strength (MPa) — log scaleBT20

BT20-DA vs BT20-STA — frequently asked

Is BT20-STA stronger than BT20-DA?

Yes. BT20-STA has a typical yield strength of 990 MPa (144 ksi) against 900 MPa (131 ksi) for BT20-DA — about 10% more. Tensile strength is 1,080 MPa (157 ksi) vs 980 MPa (142 ksi).

Which condition does FabDigit quote by default, DA or STA?

M is the default BT20 condition in the FabDigit quote flow (neither DA nor STA). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose BT20-DA over BT20-STA?

Pick BT20-DA when the part is bent, formed or impact-loaded. Pick BT20-STA when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in BT20-DA and BT20-STA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.