FabDigitFabDigit

Steel ZG270-500-F vs ZG270-500-N

Steel · ZG270-500 temper comparison

ZG270-500-F and ZG270-500-N are two conditions of the same steel grade, ZG270-500: F (as fabricated) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. ZG270-500-N is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 265 MPa (38.4 ksi) for ZG270-500-F, about 13% more; tensile strength follows at 540 MPa (78.3 ksi) vs 500 MPa (72.5 ksi). ZG270-500-N is the more ductile: elongation 22% versus 14% for ZG270-500-F.

ZG270-500-NChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

ZG270-500-F vs ZG270-500-N: properties

ZG270-500-FZG270-500-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

500 MPa72.5 ksi
540 MPa78.3 ksi

Yield Strength (0.2% offset)

265 MPa38.4 ksi
300 MPa43.5 ksi

Elongation at Break

14%
22%

Reduction in Area

22%
33%

Fatigue Strength (Endurance Limit)

210 MPa30.5 ksi
230 MPa33.4 ksi

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
27 J19.9 ft·lbf

Hardness, Brinell

155 HB
160 HB

Same in both: Elastic (Young's) Modulus 202 GPa29.3 Msi · Shear Modulus 78 GPa11.3 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 300 MPa43.5 ksi · Shear Strength 380 MPa55.1 ksi · Fracture Toughness (K_IC) 75 MPa·√m68.3 ksi·√in · Hardness, Rockwell B 84 HRB · Hardness, Vickers 168 HV

Physical

Density and transition temperatures.

Same in both: Density 7.83 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 425°C797 °F · Min Service Temperature -29°C-20 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 11 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
60%

Weldability

68 / 100
72 / 100

Same in both: Formability (cold) 25 / 100 · Castability 68 / 100 · Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleZG270-500

ZG270-500-F vs ZG270-500-N — frequently asked

Is ZG270-500-N stronger than ZG270-500-F?

Yes. ZG270-500-N has a typical yield strength of 300 MPa (43.5 ksi) against 265 MPa (38.4 ksi) for ZG270-500-F — about 13% more. Tensile strength is 540 MPa (78.3 ksi) vs 500 MPa (72.5 ksi).

Which condition does FabDigit quote by default, F or N?

N is the default ZG270-500 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, ZG270-500-F or ZG270-500-N?

ZG270-500-N. Its machinability rates good (58/100) against fair (52/100) for ZG270-500-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZG270-500-F and ZG270-500-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.