FabDigitFabDigit

Steel Y15Pb-A vs Y15Pb-CD

Steel · Y15Pb temper comparison

Y15Pb-A and Y15Pb-CD are two conditions of the same steel grade, Y15Pb: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. Y15Pb-CD is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 250 MPa (36.3 ksi) for Y15Pb-A, about 80% more; tensile strength follows at 560 MPa (81.2 ksi) vs 420 MPa (60.9 ksi). In exchange, Y15Pb-A is the more ductile: elongation 26% versus 12% for Y15Pb-CD, and Y15Pb-CD is harder (170 HB vs 130 HB).

Y15Pb-AChoose it when the part is bent, formed or impact-loaded.

Y15Pb-CDChoose it when strength drives the design.

Y15Pb-A vs Y15Pb-CD: properties

Y15Pb-AY15Pb-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

420 MPa60.9 ksi
560 MPa81.2 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
450 MPa65.3 ksi

Elongation at Break

26%
12%

Reduction in Area

50%
35%

Shear Strength

260 MPa37.7 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
240 MPa34.8 ksi

Hardness, Brinell

130 HB
170 HB

Hardness, Rockwell B

72 HRB
87 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 78 GPa11.3 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

52 W/m·K30 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11 % IACS
10.5 % IACS

Electrical Resistivity

1.57×10⁻⁷ Ω·m6.18 µΩ·in
1.65×10⁻⁷ Ω·m6.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

93 / 100
98 / 100

Machinability Rating (AISI 1212 = 100 %)

145%
160%

Weldability

14 / 100
12 / 100

Formability (cold)

50 / 100
35 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleY15Pb

Y15Pb-A vs Y15Pb-CD — frequently asked

Is Y15Pb-CD stronger than Y15Pb-A?

Yes. Y15Pb-CD has a typical yield strength of 450 MPa (65.3 ksi) against 250 MPa (36.3 ksi) for Y15Pb-A — about 80% more. Tensile strength is 560 MPa (81.2 ksi) vs 420 MPa (60.9 ksi).

Which condition does FabDigit quote by default, A or CD?

CD is the default Y15Pb condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Y15Pb-A or Y15Pb-CD?

Y15Pb-CD, by a small margin. Both rate excellent for machinability — 98/100 against 93/100 for Y15Pb-A.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Y15Pb-A and Y15Pb-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.