FabDigitFabDigit

Steel WCC-N vs WCC Q&T

Steel · WCC temper comparison

WCC-N and WCC Q&T are two conditions of the same steel grade, WCC: N (normalized) versus Q&T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. WCC Q&T is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 320 MPa (46.4 ksi) for WCC-N, about 19% more; tensile strength follows at 585 MPa (84.8 ksi) vs 550 MPa (79.8 ksi). WCC Q&T is harder — 197 HB against 185 HB for WCC-N — which matters for wear surfaces and threads.

WCC Q&TChoose it when strength drives the design, or when surface hardness matters.

WCC-N vs WCC Q&T: properties

WCC-NWCC Q&T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

550 MPa79.8 ksi
585 MPa84.8 ksi

Yield Strength (0.2% offset)

320 MPa46.4 ksi
380 MPa55.1 ksi

Reduction in Area

43%
52%

Compressive Strength

320 MPa46.4 ksi
315 MPa45.7 ksi

Shear Strength

350 MPa50.8 ksi
345 MPa50 ksi

Fatigue Strength (Endurance Limit)

235 MPa34.1 ksi
250 MPa36.3 ksi

Fracture Toughness (K_IC)

85 MPa·√m77.4 ksi·√in
90 MPa·√m81.9 ksi·√in

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

185 HB
197 HB

Hardness, Rockwell B

90 HRB
93 HRB

Hardness, Vickers

195 HV
190 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 78 GPa11.3 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Elongation at Break 24%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Min Service Temperature

-29°C-20 °F
-46°C-51 °F

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 425°C797 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.5 % IACS · Electrical Resistivity 1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

56 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
55%

Formability (cold)

19 / 100
20 / 100

Same in both: Weldability 72 / 100 · Castability 78 / 100 · Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleWCC

WCC-N vs WCC Q&T — frequently asked

Is WCC Q&T stronger than WCC-N?

Yes. WCC Q&T has a typical yield strength of 380 MPa (55.1 ksi) against 320 MPa (46.4 ksi) for WCC-N — about 19% more. Tensile strength is 585 MPa (84.8 ksi) vs 550 MPa (79.8 ksi).

Which condition does FabDigit quote by default, N or Q&T?

N+T is the default WCC condition in the FabDigit quote flow (neither N nor Q&T). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose WCC-N over WCC Q&T?

Pick WCC Q&T when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in WCC-N and WCC Q&T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.