FabDigitFabDigit

Steel WC9-ANN vs WC9 N+T

Steel · WC9 temper comparison

WC9-ANN and WC9 N+T are two conditions of the same steel grade, WC9: ANN (annealed) versus N+T (normalized and tempered). The chemistry is identical, so every difference below comes from the condition. WC9 N+T is the stronger of the two: yield strength 330 MPa (47.9 ksi) against 280 MPa (40.6 ksi) for WC9-ANN, about 18% more; tensile strength follows at 530 MPa (76.9 ksi) vs 480 MPa (69.6 ksi). In exchange, WC9-ANN is the more ductile: elongation 27% versus 24% for WC9 N+T, and WC9 N+T is harder (165 HB vs 140 HB).

WC9-ANNChoose it when the part is bent, formed or impact-loaded.

WC9 N+TChoose it when strength drives the design.

WC9-ANN vs WC9 N+T: properties

WC9-ANNWC9 N+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

480 MPa69.6 ksi
530 MPa76.9 ksi

Yield Strength (0.2% offset)

280 MPa40.6 ksi
330 MPa47.9 ksi

Elongation at Break

27%
24%

Reduction in Area

55%
50%

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

140 HB
165 HB

Hardness, Rockwell B

77 HRB
85 HRB

Hardness, Vickers

147 HV
173 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 330 MPa47.9 ksi · Shear Strength 330 MPa47.9 ksi · Fatigue Strength (Endurance Limit) 240 MPa34.8 ksi · Fracture Toughness (K_IC) 130 MPa·√m118 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 37 W/m·K21.4 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 570°C1,058 °F · Min Service Temperature -29°C-20 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 20 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

57 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
55%

Weldability

48 / 100
45 / 100

Same in both: Formability (cold) 20 / 100 · Castability 70 / 100 · Brazeability / Solderability 45 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 31 MJ/kg13,328 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleWC9

WC9-ANN vs WC9 N+T — frequently asked

Is WC9 N+T stronger than WC9-ANN?

Yes. WC9 N+T has a typical yield strength of 330 MPa (47.9 ksi) against 280 MPa (40.6 ksi) for WC9-ANN — about 18% more. Tensile strength is 530 MPa (76.9 ksi) vs 480 MPa (69.6 ksi).

Which condition does FabDigit quote by default, ANN or N+T?

N+T is the default WC9 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, WC9-ANN or WC9 N+T?

WC9-ANN. Its machinability rates good (57/100) against fair (50/100) for WC9 N+T.

Ready to make it?

Upload a CAD file and FabDigit prices the part in WC9-ANN and WC9 N+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.