FabDigitFabDigit

Steel WC11 N+T vs WC11 Q+T

Steel · WC11 temper comparison

WC11 N+T and WC11 Q+T are two conditions of the same steel grade, WC11: N+T (normalized and tempered) versus Q+T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. WC11 Q+T is the stronger of the two: yield strength 470 MPa (68.2 ksi) against 415 MPa (60.2 ksi) for WC11 N+T, about 13% more; tensile strength follows at 670 MPa (97.2 ksi) vs 620 MPa (89.9 ksi). WC11 Q+T is harder — 205 HB against 190 HB for WC11 N+T — which matters for wear surfaces and threads.

WC11 Q+TChoose it when strength drives the design, or when surface hardness matters.

WC11 N+T vs WC11 Q+T: properties

WC11 N+TWC11 Q+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
670 MPa97.2 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
470 MPa68.2 ksi

Elongation at Break

22%
21%

Reduction in Area

52%
55%

Fatigue Strength (Endurance Limit)

275 MPa39.9 ksi
300 MPa43.5 ksi

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

190 HB
205 HB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 415 MPa60.2 ksi · Shear Strength 400 MPa58 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in · Hardness, Rockwell B 92 HRB · Hardness, Vickers 200 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 40 W/m·K23.1 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 565°C1,049 °F · Min Service Temperature -29°C-20 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 16 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
50%

Weldability

60 / 100
58 / 100

Same in both: Formability (cold) 25 / 100 · Castability 72 / 100 · Brazeability / Solderability 55 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleWC11

WC11 N+T vs WC11 Q+T — frequently asked

Is WC11 Q+T stronger than WC11 N+T?

Yes. WC11 Q+T has a typical yield strength of 470 MPa (68.2 ksi) against 415 MPa (60.2 ksi) for WC11 N+T — about 13% more. Tensile strength is 670 MPa (97.2 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, N+T or Q+T?

N+T is the default WC11 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, WC11 N+T or WC11 Q+T?

WC11 N+T. Its machinability rates good (55/100) against fair (50/100) for WC11 Q+T.

Ready to make it?

Upload a CAD file and FabDigit prices the part in WC11 N+T and WC11 Q+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.