FabDigitFabDigit

Steel T8A-CD vs T8A-N

Steel · T8A temper comparison

T8A-CD and T8A-N are two conditions of the same steel grade, T8A: CD (cold drawn) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. T8A-N is the stronger of the two: tensile strength 950 MPa (138 ksi) against 700 MPa (102 ksi) for T8A-CD, about 36% more. T8A-N is harder — 285 HB against 200 HB for T8A-CD — which matters for wear surfaces and threads. On the shop floor, T8A-CD machines more easily (good vs fair) and T8A-CD forms better (30 vs 15 out of 100).

T8A-CDChoose it when the part is machined in volume.

T8A-NChoose it when strength drives the design, or when surface hardness matters.

T8A-CD vs T8A-N: properties

T8A-CDT8A-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
950 MPa138 ksi

Elongation at Break

12%
11%

Reduction in Area

35%
20%

Compressive Strength

540 MPa78.3 ksi
560 MPa81.2 ksi

Shear Strength

420 MPa60.9 ksi
570 MPa82.7 ksi

Fatigue Strength (Endurance Limit)

310 MPa45 ksi
420 MPa60.9 ksi

Charpy V-Notch Impact (RT)

10 J7.4 ft·lbf
6 J4.4 ft·lbf

Hardness, Brinell

200 HB
285 HB

Hardness, Rockwell B

93 HRB
89 HRB

Hardness, Vickers

210 HV
300 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Yield Strength (0.2% offset) 520 MPa75.4 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

48 W/m·K27.7 BTU/hr·ft·°F
45 W/m·K26 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.5 % IACS · Electrical Resistivity 1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
40%

Weldability

18 / 100
12 / 100

Formability (cold)

30 / 100
15 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleT8A

T8A-CD vs T8A-N — frequently asked

Is T8A-N stronger than T8A-CD?

Yes. T8A-N has a typical tensile strength of 950 MPa (138 ksi) against 700 MPa (102 ksi) for T8A-CD — about 36% more.

Which condition does FabDigit quote by default, CD or N?

A is the default T8A condition in the FabDigit quote flow (neither CD nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, T8A-CD or T8A-N?

T8A-CD. Its machinability rates good (55/100) against fair (38/100) for T8A-N; for welding the order is T8A-CD first (poor, 18/100) then T8A-N (not recommended, 12/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in T8A-CD and T8A-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.