FabDigitFabDigit

Steel T7-A vs T7-HR

Steel · T7 temper comparison

T7-A and T7-HR are two conditions of the same steel grade, T7: A (solution annealed) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. T7-HR is the stronger of the two: yield strength 430 MPa (62.4 ksi) against 400 MPa (58 ksi) for T7-A, about 8% more; tensile strength follows at 780 MPa (113 ksi) vs 660 MPa (95.7 ksi). In exchange, T7-A is the more ductile: elongation 22% versus 14% for T7-HR, and T7-HR is harder (225 HB vs 183 HB). On the shop floor, T7-A machines more easily (good vs fair).

T7-AChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

T7-HRChoose it when strength drives the design.

T7-A vs T7-HR: properties

T7-AT7-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

660 MPa95.7 ksi
780 MPa113 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
430 MPa62.4 ksi

Elongation at Break

22%
14%

Reduction in Area

45%
35%

Compressive Strength

420 MPa60.9 ksi
450 MPa65.3 ksi

Shear Strength

420 MPa60.9 ksi
470 MPa68.2 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
350 MPa50.8 ksi

Charpy V-Notch Impact (RT)

28 J20.7 ft·lbf
13 J9.6 ft·lbf

Hardness, Brinell

183 HB
225 HB

Hardness, Rockwell B

90 HRB
98 HRB

Hardness, Vickers

192 HV
236 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.83 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

48 W/m·K27.7 BTU/hr·ft·°F
47 W/m·K27.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.6 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.5 % IACS · Electrical Resistivity 1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
50%

Formability (cold)

45 / 100
30 / 100

Same in both: Weldability 15 / 100 · Brazeability / Solderability 55 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleT7

T7-A vs T7-HR — frequently asked

Is T7-HR stronger than T7-A?

Yes. T7-HR has a typical yield strength of 430 MPa (62.4 ksi) against 400 MPa (58 ksi) for T7-A — about 8% more. Tensile strength is 780 MPa (113 ksi) vs 660 MPa (95.7 ksi).

Which condition does FabDigit quote by default, A or HR?

A is the default T7 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, T7-A or T7-HR?

T7-A. Its machinability rates good (60/100) against fair (48/100) for T7-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in T7-A and T7-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.