FabDigitFabDigit

Steel T10A-HR vs T10A QT 54-56 HRC

Steel · T10A temper comparison

T10A-HR and T10A QT 54-56 HRC are two conditions of the same steel grade, T10A: HR (hot rolled) versus QT 54-56 HRC (quenched + tempered 300–350 °C). The chemistry is identical, so every difference below comes from the condition. T10A QT 54-56 HRC is the stronger of the two: yield strength 1,550 MPa (225 ksi) against 480 MPa (69.6 ksi) for T10A-HR, about 3.2 times as much; tensile strength follows at 1,850 MPa (268 ksi) vs 850 MPa (123 ksi). In exchange, T10A-HR is the more ductile: elongation 12% versus 2% for T10A QT 54-56 HRC, and T10A QT 54-56 HRC is harder (560 HB vs 255 HB). T10A QT 54-56 HRC runs hotter in service (250°C vs 200°C continuous). On the shop floor, T10A-HR machines more easily (fair vs not recommended).

T10A-HRChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

T10A QT 54-56 HRCChoose it when strength drives the design, or when the part sees heat.

T10A-HR vs T10A QT 54-56 HRC: properties

T10A-HRT10A QT 54-56 HRC

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

207 GPa30 Msi
210 GPa30.5 Msi

Tensile Strength (Ultimate)

850 MPa123 ksi
1,850 MPa268 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
1,550 MPa225 ksi

Elongation at Break

12%
2%

Reduction in Area

25%
4%

Compressive Strength

900 MPa131 ksi
2,400 MPa348 ksi

Shear Strength

540 MPa78.3 ksi
1,100 MPa160 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
720 MPa104 ksi

Charpy V-Notch Impact (RT)

12 J8.9 ft·lbf
9 J6.6 ft·lbf

Hardness, Brinell

255 HB
560 HB

Hardness, Vickers

268 HV
600 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Rockwell B 90 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.81 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

46 W/m·K26.6 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
250°C482 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

9.5 % IACS
8.6 % IACS

Electrical Resistivity

1.8×10⁻⁷ Ω·m7.09 µΩ·in
2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
8 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
10%

Weldability

12 / 100
4 / 100

Formability (cold)

22 / 100
2 / 100

Same in both: Brazeability / Solderability 50 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleT10A

T10A-HR vs T10A QT 54-56 HRC — frequently asked

Is T10A QT 54-56 HRC stronger than T10A-HR?

Yes. T10A QT 54-56 HRC has a typical yield strength of 1,550 MPa (225 ksi) against 480 MPa (69.6 ksi) for T10A-HR — about 3.2 times as much. Tensile strength is 1,850 MPa (268 ksi) vs 850 MPa (123 ksi).

Which condition does FabDigit quote by default, HR or QT 54-56 HRC?

Annealed is the default T10A condition in the FabDigit quote flow (neither HR nor QT 54-56 HRC). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, T10A-HR or T10A QT 54-56 HRC?

T10A-HR. Its machinability rates fair (40/100) against not recommended (8/100) for T10A QT 54-56 HRC; for welding the order is T10A-HR first (not recommended, 12/100) then T10A QT 54-56 HRC (not recommended, 4/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in T10A-HR and T10A QT 54-56 HRC side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.