FabDigitFabDigit

Steel SPCC-CR vs SPCC-HR

Steel · SPCC temper comparison

SPCC-CR and SPCC-HR are two conditions of the same steel grade, SPCC: CR (cold rolled) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. SPCC-HR is the stronger of the two: yield strength 220 MPa (31.9 ksi) against 195 MPa (28.3 ksi) for SPCC-CR, about 13% more. In exchange, SPCC-CR is the more ductile: elongation 38% versus 33% for SPCC-HR, and SPCC-HR is harder (110 HB vs 100 HB).

SPCC-CRChoose it when the part is bent, formed or impact-loaded.

SPCC-HRChoose it when strength drives the design.

SPCC-CR vs SPCC-HR: properties

SPCC-CRSPCC-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

310 MPa45 ksi
320 MPa46.4 ksi

Yield Strength (0.2% offset)

195 MPa28.3 ksi
220 MPa31.9 ksi

Elongation at Break

38%
33%

Reduction in Area

65%
60%

Compressive Strength

195 MPa28.3 ksi
220 MPa31.9 ksi

Shear Strength

230 MPa33.4 ksi
235 MPa34.1 ksi

Fatigue Strength (Endurance Limit)

165 MPa23.9 ksi
160 MPa23.2 ksi

Charpy V-Notch Impact (RT)

65 J47.9 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

100 HB
110 HB

Hardness, Rockwell B

48 HRB
55 HRB

Hardness, Vickers

110 HV
118 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 110 MPa·√m100 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,530°C2,786 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51 W/m·K29.5 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 272 J/g117 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 11 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

10 / 100
8 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
66%

Formability (cold)

90 / 100
75 / 100

Same in both: Weldability 95 / 100 · Brazeability / Solderability 75 / 100 · Polishability 30 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSPCC

SPCC-CR vs SPCC-HR — frequently asked

Is SPCC-HR stronger than SPCC-CR?

Yes. SPCC-HR has a typical yield strength of 220 MPa (31.9 ksi) against 195 MPa (28.3 ksi) for SPCC-CR — about 13% more. Tensile strength is 320 MPa (46.4 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, CR or HR?

HR is the default SPCC condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose SPCC-CR over SPCC-HR?

Pick SPCC-CR when the part is bent, formed or impact-loaded. Pick SPCC-HR when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in SPCC-CR and SPCC-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.