Steel · SNCM625 temper comparison

SNCM625-CD and SNCM625 QT-28-32HRC are two conditions of the same steel grade, SNCM625: CD (cold drawn) versus QT-28-32HRC. The chemistry is identical, so every difference below comes from the condition. SNCM625 QT-28-32HRC is the stronger of the two: yield strength 860 MPa (125 ksi) against 700 MPa (102 ksi) for SNCM625-CD, about 23% more; tensile strength follows at 990 MPa (144 ksi) vs 850 MPa (123 ksi). SNCM625 QT-28-32HRC is the more ductile: elongation 20% versus 11% for SNCM625-CD, and SNCM625 QT-28-32HRC is harder (285 HB vs 250 HB). SNCM625 QT-28-32HRC runs hotter in service (425°C vs 350°C continuous).

SNCM625 QT-28-32HRCChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

SNCM625-CD vs SNCM625 QT-28-32HRC: properties

SNCM625-CDSNCM625 QT-28-32HRC

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

850 MPa123 ksi
990 MPa144 ksi

Yield Strength (0.2% offset)

700 MPa102 ksi
860 MPa125 ksi

Elongation at Break

11%
20%

Reduction in Area

40%
56%

Compressive Strength

710 MPa103 ksi
870 MPa126 ksi

Shear Strength

510 MPa74 ksi
595 MPa86.3 ksi

Fatigue Strength (Endurance Limit)

390 MPa56.6 ksi
465 MPa67.4 ksi

Fracture Toughness (K_IC)

75 MPa·√m68.3 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
95 J70.1 ft·lbf

Hardness, Brinell

250 HB
285 HB

Hardness, Rockwell C

24 HRC
30 HRC

Hardness, Vickers

262 HV
302 HV

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

38 W/m·K22 BTU/hr·ft·°F
36 W/m·K20.8 BTU/hr·ft·°F

Max Service Temperature (continuous)

350°C662 °F
425°C797 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.5 % IACS
7.2 % IACS

Electrical Resistivity

2.3×10⁻⁷ Ω·m9.06 µΩ·in
2.4×10⁻⁷ Ω·m9.45 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 13 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
50%

Weldability

26 / 100
22 / 100

Formability (cold)

20 / 100
22 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSNCM625

SNCM625-CD vs SNCM625 QT-28-32HRC — frequently asked

Is SNCM625 QT-28-32HRC stronger than SNCM625-CD?

Yes. SNCM625 QT-28-32HRC has a typical yield strength of 860 MPa (125 ksi) against 700 MPa (102 ksi) for SNCM625-CD — about 23% more. Tensile strength is 990 MPa (144 ksi) vs 850 MPa (123 ksi).

Which condition does FabDigit quote by default, CD or QT-28-32HRC?

QT is the default SNCM625 condition in the FabDigit quote flow (neither CD nor QT-28-32HRC). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, SNCM625-CD or SNCM625 QT-28-32HRC?

SNCM625-CD, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for SNCM625 QT-28-32HRC.

Ready to make it?

Upload a CAD file and FabDigit prices the part in SNCM625-CD and SNCM625 QT-28-32HRC side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.