FabDigitFabDigit

Steel SCr415-A vs SCr415-CD

Steel · SCr415 temper comparison

SCr415-A and SCr415-CD are two conditions of the same steel grade, SCr415: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. SCr415-CD is the stronger of the two: yield strength 580 MPa (84.1 ksi) against 340 MPa (49.3 ksi) for SCr415-A, about 71% more; tensile strength follows at 710 MPa (103 ksi) vs 540 MPa (78.3 ksi). In exchange, SCr415-A is the more ductile: elongation 26% versus 12% for SCr415-CD, and SCr415-CD is harder (210 HB vs 160 HB).

SCr415-AChoose it when the part is bent, formed or impact-loaded.

SCr415-CDChoose it when strength drives the design.

SCr415-A vs SCr415-CD: properties

SCr415-ASCr415-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

540 MPa78.3 ksi
710 MPa103 ksi

Yield Strength (0.2% offset)

340 MPa49.3 ksi
580 MPa84.1 ksi

Elongation at Break

26%
12%

Reduction in Area

55%
40%

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
320 MPa46.4 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

160 HB
210 HB

Hardness, Rockwell B

84 HRB
94 HRB

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 340 MPa49.3 ksi · Shear Strength 330 MPa47.9 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 44 W/m·K25.4 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
68 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
70%

Formability (cold)

60 / 100
35 / 100

Same in both: Weldability 60 / 100 · Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 27 MJ/kg11,608 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSCr415

SCr415-A vs SCr415-CD — frequently asked

Is SCr415-CD stronger than SCr415-A?

Yes. SCr415-CD has a typical yield strength of 580 MPa (84.1 ksi) against 340 MPa (49.3 ksi) for SCr415-A — about 71% more. Tensile strength is 710 MPa (103 ksi) vs 540 MPa (78.3 ksi).

Which condition does FabDigit quote by default, A or CD?

A is the default SCr415 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, SCr415-A or SCr415-CD?

SCr415-CD, by a small margin. Both rate good for machinability — 68/100 against 60/100 for SCr415-A.

Ready to make it?

Upload a CAD file and FabDigit prices the part in SCr415-A and SCr415-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.