SCM432-CD and SCM432-QT are two conditions of the same steel grade, SCM432: CD (cold drawn) versus QT (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. SCM432-QT is the stronger of the two: yield strength 850 MPa (123 ksi) against 650 MPa (94.3 ksi) for SCM432-CD, about 31% more; tensile strength follows at 1,000 MPa (145 ksi) vs 780 MPa (113 ksi). SCM432-QT is the more ductile: elongation 17% versus 12% for SCM432-CD, and SCM432-QT is harder (293 HB vs 229 HB). SCM432-QT runs hotter in service (400°C vs 300°C continuous).

SCM432-QTChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

SCM432-CD vs SCM432-QT: properties

SCM432-CDSCM432-QT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

780 MPa113 ksi
1,000 MPa145 ksi

Yield Strength (0.2% offset)

650 MPa94.3 ksi
850 MPa123 ksi

Elongation at Break

12%
17%

Reduction in Area

40%
56%

Compressive Strength

660 MPa95.7 ksi
860 MPa125 ksi

Shear Strength

470 MPa68.2 ksi
600 MPa87 ksi

Fatigue Strength (Endurance Limit)

370 MPa53.7 ksi
470 MPa68.2 ksi

Fracture Toughness (K_IC)

65 MPa·√m59.2 ksi·√in
85 MPa·√m77.4 ksi·√in

Charpy V-Notch Impact (RT)

28 J20.7 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

229 HB
293 HB

Hardness, Rockwell C

20 HRC
31 HRC

Hardness, Vickers

241 HV
308 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

43 W/m·K24.8 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
400°C752 °F

Same in both: Specific Heat Capacity 473 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8 % IACS
7.8 % IACS

Electrical Resistivity

2.15×10⁻⁷ Ω·m8.46 µΩ·in
2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
55%

Weldability

42 / 100
45 / 100

Formability (cold)

30 / 100
40 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 28 MJ/kg12,038 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSCM432

SCM432-CD vs SCM432-QT — frequently asked

Is SCM432-QT stronger than SCM432-CD?

Yes. SCM432-QT has a typical yield strength of 850 MPa (123 ksi) against 650 MPa (94.3 ksi) for SCM432-CD — about 31% more. Tensile strength is 1,000 MPa (145 ksi) vs 780 MPa (113 ksi).

Which condition does FabDigit quote by default, CD or QT?

QT is the default SCM432 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, SCM432-CD or SCM432-QT?

SCM432-CD, by a small margin. Both rate good for machinability — 62/100 against 55/100 for SCM432-QT.

Ready to make it?

Upload a CAD file and FabDigit prices the part in SCM432-CD and SCM432-QT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.