FabDigitFabDigit

Steel SCM418-A vs SCM418-CD

Steel · SCM418 temper comparison

SCM418-A and SCM418-CD are two conditions of the same steel grade, SCM418: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. SCM418-CD is the stronger of the two: yield strength 580 MPa (84.1 ksi) against 355 MPa (51.5 ksi) for SCM418-A, about 63% more; tensile strength follows at 700 MPa (102 ksi) vs 560 MPa (81.2 ksi). In exchange, SCM418-A is the more ductile: elongation 26% versus 12% for SCM418-CD, and SCM418-CD is harder (207 HB vs 163 HB).

SCM418-AChoose it when the part is bent, formed or impact-loaded.

SCM418-CDChoose it when strength drives the design.

SCM418-A vs SCM418-CD: properties

SCM418-ASCM418-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

560 MPa81.2 ksi
700 MPa102 ksi

Yield Strength (0.2% offset)

355 MPa51.5 ksi
580 MPa84.1 ksi

Elongation at Break

26%
12%

Reduction in Area

57%
45%

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
320 MPa46.4 ksi

Hardness, Brinell

163 HB
207 HB

Hardness, Rockwell B

84 HRB
95 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 360 MPa52.2 ksi · Shear Strength 380 MPa55.1 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in · Charpy V-Notch Impact (RT) 90 J66.4 ft·lbf · Hardness, Vickers 171 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
68 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
70%

Formability (cold)

58 / 100
35 / 100

Same in both: Weldability 55 / 100 · Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSCM418

SCM418-A vs SCM418-CD — frequently asked

Is SCM418-CD stronger than SCM418-A?

Yes. SCM418-CD has a typical yield strength of 580 MPa (84.1 ksi) against 355 MPa (51.5 ksi) for SCM418-A — about 63% more. Tensile strength is 700 MPa (102 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, A or CD?

A is the default SCM418 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, SCM418-A or SCM418-CD?

SCM418-CD, by a small margin. Both rate good for machinability — 68/100 against 62/100 for SCM418-A.

Ready to make it?

Upload a CAD file and FabDigit prices the part in SCM418-A and SCM418-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.