FabDigitFabDigit

Steel SC410-F vs SC410 N+T

Steel · SC410 temper comparison

SC410-F and SC410 N+T are two conditions of the same steel grade, SC410: F (as fabricated) versus N+T (normalized and tempered). The chemistry is identical, so every difference below comes from the condition. SC410 N+T is the stronger of the two: yield strength 255 MPa (37 ksi) against 215 MPa (31.2 ksi) for SC410-F, about 19% more; tensile strength follows at 460 MPa (66.7 ksi) vs 420 MPa (60.9 ksi). SC410 N+T is the more ductile: elongation 25% versus 20% for SC410-F, and SC410 N+T is harder (135 HB vs 128 HB).

SC410 N+TChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

SC410-F vs SC410 N+T: properties

SC410-FSC410 N+T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
205 GPa29.7 Msi

Tensile Strength (Ultimate)

420 MPa60.9 ksi
460 MPa66.7 ksi

Yield Strength (0.2% offset)

215 MPa31.2 ksi
255 MPa37 ksi

Elongation at Break

20%
25%

Reduction in Area

30%
42%

Compressive Strength

220 MPa31.9 ksi
260 MPa37.7 ksi

Shear Strength

280 MPa40.6 ksi
305 MPa44.2 ksi

Fatigue Strength (Endurance Limit)

170 MPa24.7 ksi
195 MPa28.3 ksi

Fracture Toughness (K_IC)

55 MPa·√m50.1 ksi·√in
85 MPa·√m77.4 ksi·√in

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
38 J28 ft·lbf

Hardness, Brinell

128 HB
135 HB

Hardness, Rockwell B

71 HRB
74 HRB

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

48 W/m·K27.7 BTU/hr·ft·°F
49 W/m·K28.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
425°C797 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1.75×10⁻⁷ Ω·m6.89 µΩ·in
1.7×10⁻⁷ Ω·m6.69 µΩ·in

Same in both: Electrical Conductivity 10 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

11 / 100
12 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

53 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
64%

Weldability

74 / 100
76 / 100

Formability (cold)

16 / 100
22 / 100

Same in both: Castability 78 / 100 · Brazeability / Solderability 65 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleSC410

SC410-F vs SC410 N+T — frequently asked

Is SC410 N+T stronger than SC410-F?

Yes. SC410 N+T has a typical yield strength of 255 MPa (37 ksi) against 215 MPa (31.2 ksi) for SC410-F — about 19% more. Tensile strength is 460 MPa (66.7 ksi) vs 420 MPa (60.9 ksi).

Which condition does FabDigit quote by default, F or N+T?

N is the default SC410 condition in the FabDigit quote flow (neither F nor N+T). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, SC410-F or SC410 N+T?

SC410 N+T. Its machinability rates good (62/100) against fair (53/100) for SC410-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in SC410-F and SC410 N+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.