FabDigitFabDigit

Steel S50C Annealed vs S50C-CD

Steel · S50C temper comparison

S50C Annealed and S50C-CD are two conditions of the same steel grade, S50C: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. S50C-CD is the stronger of the two: yield strength 580 MPa (84.1 ksi) against 365 MPa (52.9 ksi) for S50C Annealed, about 59% more; tensile strength follows at 690 MPa (100 ksi) vs 636 MPa (92.2 ksi). In exchange, S50C Annealed is the more ductile: elongation 24% versus 10% for S50C-CD, and S50C-CD is harder (197 HB vs 187 HB).

S50C AnnealedChoose it when the part is bent, formed or impact-loaded.

S50C-CDChoose it when strength drives the design.

S50C Annealed vs S50C-CD: properties

S50C AnnealedS50C-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

636 MPa92.2 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

365 MPa52.9 ksi
580 MPa84.1 ksi

Elongation at Break

24%
10%

Reduction in Area

40%
30%

Fatigue Strength (Endurance Limit)

285 MPa41.3 ksi
310 MPa45 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

187 HB
197 HB

Hardness, Rockwell B

90 HRB
93 HRB

Hardness, Vickers

196 HV
228 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 430 MPa62.4 ksi · Shear Strength 450 MPa65.3 ksi · Fracture Toughness (K_IC) 50 MPa·√m45.5 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 49 W/m·K28.3 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

40 / 100
35 / 100

Formability (cold)

45 / 100
25 / 100

Same in both: Machinability 55 / 100 · Machinability Rating (AISI 1212 = 100 %) 55% · Castability 55 / 100 · Brazeability / Solderability 60 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS50C

S50C Annealed vs S50C-CD — frequently asked

Is S50C-CD stronger than S50C Annealed?

Yes. S50C-CD has a typical yield strength of 580 MPa (84.1 ksi) against 365 MPa (52.9 ksi) for S50C Annealed — about 59% more. Tensile strength is 690 MPa (100 ksi) vs 636 MPa (92.2 ksi).

Which condition does FabDigit quote by default, Annealed or CD?

Normalized is the default S50C condition in the FabDigit quote flow (neither Annealed nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, S50C Annealed or S50C-CD?

S50C Annealed. Its weldability rates fair (40/100) against fair (35/100) for S50C-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S50C Annealed and S50C-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.