S35C-CD and S35C-N are two conditions of the same steel grade, S35C: CD (cold drawn) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. S35C-CD is the stronger of the two: yield strength 530 MPa (76.9 ksi) against 340 MPa (49.3 ksi) for S35C-N, about 56% more; tensile strength follows at 620 MPa (89.9 ksi) vs 560 MPa (81.2 ksi). In exchange, S35C-N is the more ductile: elongation 25% versus 12% for S35C-CD, and S35C-CD is harder (185 HB vs 170 HB).

S35C-CDChoose it when strength drives the design.

S35C-NChoose it when the part is bent, formed or impact-loaded.

S35C-CD vs S35C-N: properties

S35C-CDS35C-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
560 MPa81.2 ksi

Yield Strength (0.2% offset)

530 MPa76.9 ksi
340 MPa49.3 ksi

Elongation at Break

12%
25%

Reduction in Area

40%
55%

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
260 MPa37.7 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

185 HB
170 HB

Hardness, Rockwell B

90 HRB
86 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 380 MPa55.1 ksi · Fracture Toughness (K_IC) 55 MPa·√m50.1 ksi·√in · Hardness, Vickers 180 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

66 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
65%

Weldability

60 / 100
65 / 100

Formability (cold)

35 / 100
50 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS35C

S35C-CD vs S35C-N — frequently asked

Is S35C-CD stronger than S35C-N?

Yes. S35C-CD has a typical yield strength of 530 MPa (76.9 ksi) against 340 MPa (49.3 ksi) for S35C-N — about 56% more. Tensile strength is 620 MPa (89.9 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, CD or N?

N is the default S35C condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, S35C-CD or S35C-N?

S35C-CD, by a small margin. Both rate good for machinability — 66/100 against 60/100 for S35C-N; for welding the order is S35C-N first (good, 65/100) then S35C-CD (good, 60/100).