FabDigitFabDigit

Steel S35C-A vs S35C-CD

Steel · S35C temper comparison

S35C-A and S35C-CD are two conditions of the same steel grade, S35C: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. S35C-CD is the stronger of the two: yield strength 530 MPa (76.9 ksi) against 280 MPa (40.6 ksi) for S35C-A, about 89% more; tensile strength follows at 620 MPa (89.9 ksi) vs 500 MPa (72.5 ksi). In exchange, S35C-A is the more ductile: elongation 30% versus 12% for S35C-CD, and S35C-CD is harder (185 HB vs 143 HB).

S35C-AChoose it when the part is bent, formed or impact-loaded.

S35C-CDChoose it when strength drives the design.

S35C-A vs S35C-CD: properties

S35C-AS35C-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

500 MPa72.5 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

280 MPa40.6 ksi
530 MPa76.9 ksi

Elongation at Break

30%
12%

Reduction in Area

58%
40%

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
280 MPa40.6 ksi

Charpy V-Notch Impact (RT)

50 J36.9 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

143 HB
185 HB

Hardness, Rockwell B

78 HRB
90 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Shear Strength 380 MPa55.1 ksi · Fracture Toughness (K_IC) 55 MPa·√m50.1 ksi·√in · Hardness, Vickers 180 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
66 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
70%

Weldability

68 / 100
60 / 100

Formability (cold)

58 / 100
35 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS35C

S35C-A vs S35C-CD — frequently asked

Is S35C-CD stronger than S35C-A?

Yes. S35C-CD has a typical yield strength of 530 MPa (76.9 ksi) against 280 MPa (40.6 ksi) for S35C-A — about 89% more. Tensile strength is 620 MPa (89.9 ksi) vs 500 MPa (72.5 ksi).

Which condition does FabDigit quote by default, A or CD?

N is the default S35C condition in the FabDigit quote flow (neither A nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, S35C-A or S35C-CD?

S35C-CD, by a small margin. Both rate good for machinability — 66/100 against 58/100 for S35C-A; for welding the order is S35C-A first (good, 68/100) then S35C-CD (good, 60/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in S35C-A and S35C-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.