FabDigitFabDigit

Steel S30C-A vs S30C-N

Steel · S30C temper comparison

S30C-A and S30C-N are two conditions of the same steel grade, S30C: A (solution annealed) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. S30C-N is the stronger of the two: yield strength 330 MPa (47.9 ksi) against 280 MPa (40.6 ksi) for S30C-A, about 18% more; tensile strength follows at 520 MPa (75.4 ksi) vs 465 MPa (67.4 ksi). In exchange, S30C-A is the more ductile: elongation 31% versus 26% for S30C-N, and S30C-N is harder (156 HB vs 137 HB).

S30C-AChoose it when the part is bent, formed or impact-loaded.

S30C-NChoose it when strength drives the design.

S30C-A vs S30C-N: properties

S30C-AS30C-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

465 MPa67.4 ksi
520 MPa75.4 ksi

Yield Strength (0.2% offset)

280 MPa40.6 ksi
330 MPa47.9 ksi

Elongation at Break

31%
26%

Reduction in Area

58%
52%

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
250 MPa36.3 ksi

Charpy V-Notch Impact (RT)

50 J36.9 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

137 HB
156 HB

Hardness, Rockwell B

76 HRB
82 HRB

Hardness, Vickers

144 HV
164 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 330 MPa47.9 ksi · Shear Strength 390 MPa56.6 ksi · Fracture Toughness (K_IC) 65 MPa·√m59.2 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 51 W/m·K29.5 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

58 / 100
50 / 100

Same in both: Machinability 62 / 100 · Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 65 / 100 · Castability 40 / 100 · Brazeability / Solderability 70 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS30C

S30C-A vs S30C-N — frequently asked

Is S30C-N stronger than S30C-A?

Yes. S30C-N has a typical yield strength of 330 MPa (47.9 ksi) against 280 MPa (40.6 ksi) for S30C-A — about 18% more. Tensile strength is 520 MPa (75.4 ksi) vs 465 MPa (67.4 ksi).

Which condition does FabDigit quote by default, A or N?

N is the default S30C condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose S30C-A over S30C-N?

Pick S30C-A when the part is bent, formed or impact-loaded. Pick S30C-N when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S30C-A and S30C-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.