FabDigitFabDigit

Steel S2 Normalized vs S2 Q&T

Steel · S2 temper comparison

S2 Normalized and S2 Q&T are two conditions of the same steel grade, S2: Normalized versus Q&T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. S2 Q&T is the stronger of the two: yield strength 1,700 MPa (247 ksi) against 700 MPa (102 ksi) for S2 Normalized, about 143% more; tensile strength follows at 2,000 MPa (290 ksi) vs 1,050 MPa (152 ksi). In exchange, S2 Normalized is the more ductile: elongation 12% versus 6% for S2 Q&T, and S2 Normalized is harder (300 HB vs 200 HB). On the shop floor, S2 Normalized machines more easily (poor vs not recommended).

S2 NormalizedChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

S2 Q&TChoose it when strength drives the design.

S2 Normalized vs S2 Q&T: properties

S2 NormalizedS2 Q&T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,050 MPa152 ksi
2,000 MPa290 ksi

Yield Strength (0.2% offset)

700 MPa102 ksi
1,700 MPa247 ksi

Elongation at Break

12%
6%

Reduction in Area

35%
15%

Compressive Strength

720 MPa104 ksi
2,700 MPa392 ksi

Shear Strength

630 MPa91.4 ksi
1,200 MPa174 ksi

Fatigue Strength (Endurance Limit)

470 MPa68.2 ksi
750 MPa109 ksi

Fracture Toughness (K_IC)

55 MPa·√m50.1 ksi·√in
35 MPa·√m31.9 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

300 HB
200 HB

Hardness, Vickers

315 HV
640 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Rockwell B 94 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.79 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

25 W/m·K14.4 BTU/hr·ft·°F
25.5 W/m·K14.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 477 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.5 µm/m·K6.9 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 5.5 % IACS · Electrical Resistivity 3.1×10⁻⁷ Ω·m12.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
12 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
65%

Weldability

10 / 100
15 / 100

Formability (cold)

15 / 100
5 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 35 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 65 L/kg7.8 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleS2

S2 Normalized vs S2 Q&T — frequently asked

Is S2 Q&T stronger than S2 Normalized?

Yes. S2 Q&T has a typical yield strength of 1,700 MPa (247 ksi) against 700 MPa (102 ksi) for S2 Normalized — about 143% more. Tensile strength is 2,000 MPa (290 ksi) vs 1,050 MPa (152 ksi).

Which condition does FabDigit quote by default, Normalized or Q&T?

Annealed is the default S2 condition in the FabDigit quote flow (neither Normalized nor Q&T). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, S2 Normalized or S2 Q&T?

S2 Normalized. Its machinability rates poor (30/100) against not recommended (12/100) for S2 Q&T; for welding the order is S2 Q&T first (poor, 15/100) then S2 Normalized (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in S2 Normalized and S2 Q&T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.