Steel · Q235A temper comparison

Q235A-CR and Q235A-N are two conditions of the same steel grade, Q235A: CR (cold rolled) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. Q235A-CR is the stronger of the two: yield strength 340 MPa (49.3 ksi) against 250 MPa (36.3 ksi) for Q235A-N, about 36% more; tensile strength follows at 450 MPa (65.3 ksi) vs 410 MPa (59.5 ksi). In exchange, Q235A-N is the more ductile: elongation 31% versus 16% for Q235A-CR, and Q235A-CR is harder (150 HB vs 121 HB). Q235A-N runs hotter in service (350°C vs 300°C continuous).

Q235A-CRChoose it when strength drives the design.

Q235A-NChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Q235A-CR vs Q235A-N: properties

Q235A-CRQ235A-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

205 GPa29.7 Msi
206 GPa29.9 Msi

Tensile Strength (Ultimate)

450 MPa65.3 ksi
410 MPa59.5 ksi

Yield Strength (0.2% offset)

340 MPa49.3 ksi
250 MPa36.3 ksi

Elongation at Break

16%
31%

Reduction in Area

45%
60%

Compressive Strength

340 MPa49.3 ksi
250 MPa36.3 ksi

Shear Strength

280 MPa40.6 ksi
255 MPa37 ksi

Fatigue Strength (Endurance Limit)

200 MPa29 ksi
180 MPa26.1 ksi

Fracture Toughness (K_IC)

50 MPa·√m45.5 ksi·√in
70 MPa·√m63.7 ksi·√in

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

150 HB
121 HB

Hardness, Rockwell B

80 HRB
67 HRB

Hardness, Vickers

158 HV
127 HV

Same in both: Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

50 W/m·K28.9 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
350°C662 °F

Same in both: Specific Heat Capacity 472 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature 0°C32 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.2 % IACS
10.5 % IACS

Electrical Resistivity

1.66×10⁻⁷ Ω·m6.54 µΩ·in
1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

67 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
65%

Weldability

88 / 100
93 / 100

Formability (cold)

70 / 100
85 / 100

Polishability

55 / 100
45 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 35 L/kg4.2 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleQ235A

Q235A-CR vs Q235A-N — frequently asked

Is Q235A-CR stronger than Q235A-N?

Yes. Q235A-CR has a typical yield strength of 340 MPa (49.3 ksi) against 250 MPa (36.3 ksi) for Q235A-N — about 36% more. Tensile strength is 450 MPa (65.3 ksi) vs 410 MPa (59.5 ksi).

Which condition does FabDigit quote by default, CR or N?

HR is the default Q235A condition in the FabDigit quote flow (neither CR nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Q235A-CR or Q235A-N?

Q235A-CR, by a small margin. Both rate good for machinability — 67/100 against 62/100 for Q235A-N; for welding the order is Q235A-N first (excellent, 93/100) then Q235A-CR (excellent, 88/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Q235A-CR and Q235A-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.