FabDigitFabDigit

Steel Q235A-A vs Q235A-CR

Steel · Q235A temper comparison

Q235A-A and Q235A-CR are two conditions of the same steel grade, Q235A: A (solution annealed) versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. Q235A-CR is the stronger of the two: yield strength 340 MPa (49.3 ksi) against 240 MPa (34.8 ksi) for Q235A-A, about 42% more; tensile strength follows at 450 MPa (65.3 ksi) vs 385 MPa (55.8 ksi). In exchange, Q235A-A is the more ductile: elongation 34% versus 16% for Q235A-CR, and Q235A-CR is harder (150 HB vs 112 HB). Q235A-A runs hotter in service (350°C vs 300°C continuous).

Q235A-AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Q235A-CRChoose it when strength drives the design.

Q235A-A vs Q235A-CR: properties

Q235A-AQ235A-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

206 GPa29.9 Msi
205 GPa29.7 Msi

Tensile Strength (Ultimate)

385 MPa55.8 ksi
450 MPa65.3 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
340 MPa49.3 ksi

Elongation at Break

34%
16%

Reduction in Area

63%
45%

Compressive Strength

240 MPa34.8 ksi
340 MPa49.3 ksi

Shear Strength

240 MPa34.8 ksi
280 MPa40.6 ksi

Fatigue Strength (Endurance Limit)

170 MPa24.7 ksi
200 MPa29 ksi

Fracture Toughness (K_IC)

75 MPa·√m68.3 ksi·√in
50 MPa·√m45.5 ksi·√in

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

112 HB
150 HB

Hardness, Rockwell B

62 HRB
80 HRB

Hardness, Vickers

118 HV
158 HV

Same in both: Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

52 W/m·K30 BTU/hr·ft·°F
50 W/m·K28.9 BTU/hr·ft·°F

Max Service Temperature (continuous)

350°C662 °F
300°C572 °F

Same in both: Specific Heat Capacity 472 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature 0°C32 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.7 % IACS
10.2 % IACS

Electrical Resistivity

1.58×10⁻⁷ Ω·m6.22 µΩ·in
1.66×10⁻⁷ Ω·m6.54 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

59 / 100
67 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
70%

Weldability

94 / 100
88 / 100

Formability (cold)

90 / 100
70 / 100

Polishability

45 / 100
55 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 35 L/kg4.2 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleQ235A

Q235A-A vs Q235A-CR — frequently asked

Is Q235A-CR stronger than Q235A-A?

Yes. Q235A-CR has a typical yield strength of 340 MPa (49.3 ksi) against 240 MPa (34.8 ksi) for Q235A-A — about 42% more. Tensile strength is 450 MPa (65.3 ksi) vs 385 MPa (55.8 ksi).

Which condition does FabDigit quote by default, A or CR?

HR is the default Q235A condition in the FabDigit quote flow (neither A nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Q235A-A or Q235A-CR?

Q235A-CR, by a small margin. Both rate good for machinability — 67/100 against 59/100 for Q235A-A; for welding the order is Q235A-A first (excellent, 94/100) then Q235A-CR (excellent, 88/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Q235A-A and Q235A-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.