FabDigitFabDigit

Steel Q215-CD vs Q215-HR

Steel · Q215 temper comparison

Q215-CD and Q215-HR are two conditions of the same steel grade, Q215: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. Q215-CD is the stronger of the two: yield strength 400 MPa (58 ksi) against 235 MPa (34.1 ksi) for Q215-HR, about 70% more; tensile strength follows at 500 MPa (72.5 ksi) vs 390 MPa (56.6 ksi). In exchange, Q215-HR is the more ductile: elongation 33% versus 12% for Q215-CD, and Q215-CD is harder (150 HB vs 116 HB). Q215-HR runs hotter in service (350°C vs 250°C continuous).

Q215-CDChoose it when strength drives the design.

Q215-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Q215-CD vs Q215-HR: properties

Q215-CDQ215-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

500 MPa72.5 ksi
390 MPa56.6 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
235 MPa34.1 ksi

Elongation at Break

12%
33%

Reduction in Area

45%
58%

Compressive Strength

410 MPa59.5 ksi
235 MPa34.1 ksi

Shear Strength

320 MPa46.4 ksi
260 MPa37.7 ksi

Fatigue Strength (Endurance Limit)

220 MPa31.9 ksi
175 MPa25.4 ksi

Fracture Toughness (K_IC)

90 MPa·√m81.9 ksi·√in
130 MPa·√m118 ksi·√in

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

150 HB
116 HB

Hardness, Rockwell B

80 HRB
65 HRB

Hardness, Vickers

158 HV
122 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,525°C2,777 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

250°C482 °F
350°C662 °F

Same in both: Thermal Conductivity 51 W/m·K29.5 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.5 % IACS
11 % IACS

Electrical Resistivity

1.65×10⁻⁷ Ω·m6.5 µΩ·in
1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
65%

Weldability

88 / 100
95 / 100

Formability (cold)

60 / 100
90 / 100

Same in both: Brazeability / Solderability 70 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleQ215

Q215-CD vs Q215-HR — frequently asked

Is Q215-CD stronger than Q215-HR?

Yes. Q215-CD has a typical yield strength of 400 MPa (58 ksi) against 235 MPa (34.1 ksi) for Q215-HR — about 70% more. Tensile strength is 500 MPa (72.5 ksi) vs 390 MPa (56.6 ksi).

Which condition does FabDigit quote by default, CD or HR?

HR is the default Q215 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Q215-CD or Q215-HR?

Q215-CD, by a small margin. Both rate good for machinability — 68/100 against 62/100 for Q215-HR; for welding the order is Q215-HR first (excellent, 95/100) then Q215-CD (excellent, 88/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Q215-CD and Q215-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.