FabDigitFabDigit

Steel P275NH-N vs P275NH N-100-150

Steel · P275NH temper comparison

P275NH-N and P275NH N-100-150 are two conditions of the same steel grade, P275NH: N (normalized) versus N-100-150 (n). The chemistry is identical, so every difference below comes from the condition. P275NH-N is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 240 MPa (34.8 ksi) for P275NH N-100-150, about 25% more; tensile strength follows at 450 MPa (65.3 ksi) vs 410 MPa (59.5 ksi). P275NH-N is the more ductile: elongation 30% versus 27% for P275NH N-100-150, and P275NH-N is harder (135 HB vs 124 HB).

P275NH-NChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

P275NH-N vs P275NH N-100-150: properties

P275NH-NP275NH N-100-150

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

450 MPa65.3 ksi
410 MPa59.5 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
240 MPa34.8 ksi

Elongation at Break

30%
27%

Reduction in Area

55%
51%

Compressive Strength

300 MPa43.5 ksi
228 MPa33.1 ksi

Shear Strength

295 MPa42.8 ksi
266 MPa38.6 ksi

Fatigue Strength (Endurance Limit)

195 MPa28.3 ksi
176 MPa25.5 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

120 J88.5 ft·lbf
80 J59 ft·lbf

Hardness, Brinell

135 HB
124 HB

Hardness, Rockwell B

75 HRB
69 HRB

Hardness, Vickers

142 HV
130 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,490°C2,714 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.5 % IACS · Electrical Resistivity 1.65×10⁻⁷ Ω·m6.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
67%

Weldability

90 / 100
86 / 100

Formability (cold)

70 / 100
65 / 100

Same in both: Castability 0 / 100 · Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleP275NH

P275NH-N vs P275NH N-100-150 — frequently asked

Is P275NH-N stronger than P275NH N-100-150?

Yes. P275NH-N has a typical yield strength of 300 MPa (43.5 ksi) against 240 MPa (34.8 ksi) for P275NH N-100-150 — about 25% more. Tensile strength is 450 MPa (65.3 ksi) vs 410 MPa (59.5 ksi).

Which condition does FabDigit quote by default, N or N-100-150?

N is the default P275NH condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose P275NH-N over P275NH N-100-150?

Pick P275NH-N when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in P275NH-N and P275NH N-100-150 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.