P265GH Annealed and P265GH-HR are two conditions of the same steel grade, P265GH: Annealed versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. P265GH-HR is the stronger of the two: yield strength 295 MPa (42.8 ksi) against 275 MPa (39.9 ksi) for P265GH Annealed, about 7% more; tensile strength follows at 465 MPa (67.4 ksi) vs 430 MPa (62.4 ksi). In exchange, P265GH Annealed is the more ductile: elongation 32% versus 26% for P265GH-HR, and P265GH-HR is harder (140 HB vs 120 HB).

P265GH AnnealedChoose it when the part is bent, formed or impact-loaded.

P265GH-HRChoose it when strength drives the design.

P265GH Annealed vs P265GH-HR: properties

P265GH AnnealedP265GH-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

430 MPa62.4 ksi
465 MPa67.4 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
295 MPa42.8 ksi

Elongation at Break

32%
26%

Reduction in Area

60%
52%

Compressive Strength

275 MPa39.9 ksi
295 MPa42.8 ksi

Shear Strength

260 MPa37.7 ksi
280 MPa40.6 ksi

Fatigue Strength (Endurance Limit)

195 MPa28.3 ksi
205 MPa29.7 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

85 J62.7 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

120 HB
140 HB

Hardness, Rockwell B

67 HRB
76 HRB

Hardness, Vickers

126 HV
147 HV

Same in both: Elastic (Young's) Modulus 211 GPa30.6 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51 W/m·K29.5 BTU/hr·ft·°F
50 W/m·K28.9 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 461 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -10°C14 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
66 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
63%

Weldability

92 / 100
90 / 100

Formability (cold)

85 / 100
76 / 100

Same in both: Brazeability / Solderability 70 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleP265GH

P265GH Annealed vs P265GH-HR — frequently asked

Is P265GH-HR stronger than P265GH Annealed?

Yes. P265GH-HR has a typical yield strength of 295 MPa (42.8 ksi) against 275 MPa (39.9 ksi) for P265GH Annealed — about 7% more. Tensile strength is 465 MPa (67.4 ksi) vs 430 MPa (62.4 ksi).

Which condition does FabDigit quote by default, Annealed or HR?

HR is the default P265GH condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, P265GH Annealed or P265GH-HR?

P265GH Annealed. Its machinability rates very good (72/100) against good (66/100) for P265GH-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in P265GH Annealed and P265GH-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.