FabDigitFabDigit

Steel M30-HR vs M30 HT-62

Steel · M30 temper comparison

M30-HR and M30 HT-62 are two conditions of the same steel grade, M30: HR (hot rolled) versus HT-62 (hardened & tempered). The chemistry is identical, so every difference below comes from the condition. M30-HR is the stronger of the two: yield strength 800 MPa (116 ksi) against 590 MPa (85.6 ksi) for M30 HT-62, about 36% more; tensile strength follows at 1,080 MPa (157 ksi) vs 900 MPa (131 ksi). In exchange, M30 HT-62 is the more ductile: elongation 15% versus 8% for M30-HR, and M30-HR is harder (320 HB vs 235 HB). M30 HT-62 runs hotter in service (560°C vs 480°C continuous) and M30-HR conducts heat better (24 W/m·K vs 21 W/m·K). On the shop floor, M30-HR machines more easily (poor vs not recommended).

M30-HRChoose it when strength drives the design, or when the part is machined in volume.

M30 HT-62Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

M30-HR vs M30 HT-62: properties

M30-HRM30 HT-62

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

217 GPa31.5 Msi
222 GPa32.2 Msi

Tensile Strength (Ultimate)

1,080 MPa157 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

800 MPa116 ksi
590 MPa85.6 ksi

Elongation at Break

8%
15%

Reduction in Area

16%
28%

Compressive Strength

1,200 MPa174 ksi
3,800 MPa551 ksi

Shear Strength

700 MPa102 ksi
600 MPa87 ksi

Fatigue Strength (Endurance Limit)

480 MPa69.6 ksi
750 MPa109 ksi

Charpy V-Notch Impact (RT)

10 J7.4 ft·lbf
7 J5.2 ft·lbf

Hardness, Brinell

320 HB
235 HB

Hardness, Vickers

336 HV
750 HV

Same in both: Shear Modulus 83 GPa12 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28 · Hardness, Rockwell B 99 HRB

Physical

Density and transition temperatures.

Same in both: Density 8.03 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,260°C2,300 °F · Liquidus Temperature 1,425°C2,597 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

24 W/m·K13.9 BTU/hr·ft·°F
21 W/m·K12.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

480°C896 °F
560°C1,040 °F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.5 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.9 % IACS · Electrical Resistivity 6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.58 V · Corrosion Resistance 15 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

20 / 100
10 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
40%

Weldability

10 / 100
15 / 100

Formability (cold)

5 / 100
15 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 90 L/kg10.8 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleM30

M30-HR vs M30 HT-62 — frequently asked

Is M30-HR stronger than M30 HT-62?

Yes. M30-HR has a typical yield strength of 800 MPa (116 ksi) against 590 MPa (85.6 ksi) for M30 HT-62 — about 36% more. Tensile strength is 1,080 MPa (157 ksi) vs 900 MPa (131 ksi).

Which condition does FabDigit quote by default, HR or HT-62?

ANN is the default M30 condition in the FabDigit quote flow (neither HR nor HT-62). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, M30-HR or M30 HT-62?

M30-HR. Its machinability rates poor (20/100) against not recommended (10/100) for M30 HT-62; for welding the order is M30 HT-62 first (poor, 15/100) then M30-HR (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in M30-HR and M30 HT-62 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.