FabDigitFabDigit

Steel L3 QT-55 vs L3 QT-62

Steel · L3 temper comparison

L3 QT-55 and L3 QT-62 are two conditions of the same steel grade, L3: QT-55 (hardened & tempered 315–370 °C) versus QT-62 (hardened & tempered 150–175 °C). The chemistry is identical, so every difference below comes from the condition. L3 QT-62 is the stronger of the two: yield strength 2,050 MPa (297 ksi) against 1,650 MPa (239 ksi) for L3 QT-55, about 24% more; tensile strength follows at 2,350 MPa (341 ksi) vs 1,900 MPa (276 ksi). In exchange, L3 QT-55 is the more ductile: elongation 4% versus 1% for L3 QT-62, and L3 QT-62 is harder (790 HV vs 600 HV). L3 QT-55 runs hotter in service (260°C vs 150°C continuous) and L3 QT-55 conducts heat better (38 W/m·K vs 34 W/m·K). On the shop floor, L3 QT-55 welds better (poor vs not recommended).

L3 QT-55Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

L3 QT-62Choose it when strength drives the design.

L3 QT-55 vs L3 QT-62: properties

L3 QT-55L3 QT-62

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,900 MPa276 ksi
2,350 MPa341 ksi

Yield Strength (0.2% offset)

1,650 MPa239 ksi
2,050 MPa297 ksi

Elongation at Break

4%
1%

Reduction in Area

12%
2%

Compressive Strength

450 MPa65.3 ksi
3,000 MPa435 ksi

Shear Strength

480 MPa69.6 ksi
1,500 MPa218 ksi

Fatigue Strength (Endurance Limit)

760 MPa110 ksi
750 MPa109 ksi

Charpy V-Notch Impact (RT)

16 J11.8 ft·lbf
5 J3.7 ft·lbf

Hardness, Vickers

600 HV
790 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Brinell 197 HB · Hardness, Rockwell B 92 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

38 W/m·K22 BTU/hr·ft·°F
34 W/m·K19.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

260°C500 °F
150°C302 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

14 / 100
8 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
5%

Weldability

15 / 100
5 / 100

Formability (cold)

35 / 100
2 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 45 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.5 kg CO₂/kg · Embodied Water 70 L/kg8.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleL3

L3 QT-55 vs L3 QT-62 — frequently asked

Is L3 QT-62 stronger than L3 QT-55?

Yes. L3 QT-62 has a typical yield strength of 2,050 MPa (297 ksi) against 1,650 MPa (239 ksi) for L3 QT-55 — about 24% more. Tensile strength is 2,350 MPa (341 ksi) vs 1,900 MPa (276 ksi).

Which condition does FabDigit quote by default, QT-55 or QT-62?

ANN is the default L3 condition in the FabDigit quote flow (neither QT-55 nor QT-62). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, L3 QT-55 or L3 QT-62?

L3 QT-55, by a small margin. Both rate not recommended for machinability — 14/100 against 8/100 for L3 QT-62; for welding the order is L3 QT-55 first (poor, 15/100) then L3 QT-62 (not recommended, 5/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in L3 QT-55 and L3 QT-62 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.