FabDigitFabDigit

Steel L1-HR vs L1-SR

Steel · L1 temper comparison

L1-HR and L1-SR are two conditions of the same steel grade, L1: HR (hot rolled) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. L1-HR is the stronger of the two: yield strength 490 MPa (71.1 ksi) against 430 MPa (62.4 ksi) for L1-SR, about 14% more; tensile strength follows at 850 MPa (123 ksi) vs 740 MPa (107 ksi). In exchange, L1-SR is the more ductile: elongation 20% versus 14% for L1-HR, and L1-HR is harder (240 HB vs 200 HB). On the shop floor, L1-SR machines more easily (good vs fair).

L1-HRChoose it when strength drives the design.

L1-SRChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

L1-HR vs L1-SR: properties

L1-HRL1-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

850 MPa123 ksi
740 MPa107 ksi

Yield Strength (0.2% offset)

490 MPa71.1 ksi
430 MPa62.4 ksi

Elongation at Break

14%
20%

Reduction in Area

35%
45%

Compressive Strength

505 MPa73.2 ksi
445 MPa64.5 ksi

Shear Strength

525 MPa76.1 ksi
460 MPa66.7 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
345 MPa50 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
36 J26.6 ft·lbf

Hardness, Brinell

240 HB
200 HB

Hardness, Rockwell B

99 HRB
93 HRB

Hardness, Vickers

252 HV
210 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,460°C2,660 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 41 W/m·K23.7 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8.5 % IACS · Electrical Resistivity 2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
65%

Weldability

10 / 100
12 / 100

Formability (cold)

18 / 100
28 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 33 MJ/kg14,187 BTU/lb · Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 65 L/kg7.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleL1

L1-HR vs L1-SR — frequently asked

Is L1-HR stronger than L1-SR?

Yes. L1-HR has a typical yield strength of 490 MPa (71.1 ksi) against 430 MPa (62.4 ksi) for L1-SR — about 14% more. Tensile strength is 850 MPa (123 ksi) vs 740 MPa (107 ksi).

Which condition does FabDigit quote by default, HR or SR?

ANN is the default L1 condition in the FabDigit quote flow (neither HR nor SR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, L1-HR or L1-SR?

L1-SR. Its machinability rates good (55/100) against fair (42/100) for L1-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in L1-HR and L1-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.