Steel H22-HR vs H22-QT45

Steel · H22 temper comparison

H22-HR and H22-QT45 are two conditions of the same steel grade, H22: HR (hot rolled) versus QT45 (hardened & tempered 44–46 HRC). The chemistry is identical, so every difference below comes from the condition. H22-QT45 is the stronger of the two: yield strength 1,250 MPa (181 ksi) against 900 MPa (131 ksi) for H22-HR, about 39% more; tensile strength follows at 1,470 MPa (213 ksi) vs 1,150 MPa (167 ksi). In exchange, H22-HR is the more ductile: elongation 10% versus 9% for H22-QT45, and H22-QT45 is harder (421 HB vs 340 HB). H22-QT45 runs hotter in service (620°C vs 500°C continuous).

H22-HRChoose it when the part is bent, formed or impact-loaded.

H22-QT45Choose it when strength drives the design, or when the part sees heat.

H22-HR vs H22-QT45: properties

H22-HRH22-QT45

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

207 GPa30 Msi
210 GPa30.5 Msi

Tensile Strength (Ultimate)

1,150 MPa167 ksi
1,470 MPa213 ksi

Yield Strength (0.2% offset)

900 MPa131 ksi
1,250 MPa181 ksi

Elongation at Break

10%
9%

Reduction in Area

24%
30%

Compressive Strength

1,000 MPa145 ksi
1,650 MPa239 ksi

Shear Strength

700 MPa102 ksi
900 MPa131 ksi

Fatigue Strength (Endurance Limit)

510 MPa74 ksi
620 MPa89.9 ksi

Charpy V-Notch Impact (RT)

11 J8.1 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

340 HB
421 HB

Hardness, Vickers

360 HV
446 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 32 MPa·√m29.1 ksi·√in · Hardness, Rockwell B 95 HRB

Physical

Density and transition temperatures.

Same in both: Density 8.45 g/cm³0.31 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,475°C2,687 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

26 W/m·K15 BTU/hr·ft·°F
27 W/m·K15.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

500°C932 °F
620°C1,148 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11 µm/m·K6.1 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

3 % IACS
3.1 % IACS

Electrical Resistivity

5.7×10⁻⁷ Ω·m22.4 µΩ·in
5.5×10⁻⁷ Ω·m21.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

16 / 100
17 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.55 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

18 / 100
12 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
12%

Weldability

12 / 100
20 / 100

Formability (cold)

5 / 100
15 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 35 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 75 L/kg9 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleH22

H22-HR vs H22-QT45 — frequently asked

Is H22-QT45 stronger than H22-HR?

Yes. H22-QT45 has a typical yield strength of 1,250 MPa (181 ksi) against 900 MPa (131 ksi) for H22-HR — about 39% more. Tensile strength is 1,470 MPa (213 ksi) vs 1,150 MPa (167 ksi).

Which condition does FabDigit quote by default, HR or QT45?

ANN is the default H22 condition in the FabDigit quote flow (neither HR nor QT45). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, H22-HR or H22-QT45?

H22-HR. Its machinability rates poor (18/100) against not recommended (12/100) for H22-QT45; for welding the order is H22-QT45 first (poor, 20/100) then H22-HR (not recommended, 12/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in H22-HR and H22-QT45 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.