FabDigitFabDigit

Steel H22-ANN vs H22-QT50

Steel · H22 temper comparison

H22-ANN and H22-QT50 are two conditions of the same steel grade, H22: ANN (annealed) versus QT50 (hardened & tempered 48–52 HRC). The chemistry is identical, so every difference below comes from the condition. H22-QT50 is the stronger of the two: yield strength 1,450 MPa (210 ksi) against 470 MPa (68.2 ksi) for H22-ANN, about 3.1 times as much; tensile strength follows at 1,720 MPa (249 ksi) vs 790 MPa (115 ksi). In exchange, H22-ANN is the more ductile: elongation 18% versus 7% for H22-QT50, and H22-QT50 is harder (481 HB vs 212 HB). H22-QT50 runs hotter in service (600°C vs 500°C continuous). On the shop floor, H22-ANN machines more easily (poor vs not recommended) and H22-ANN welds better (30 vs 18 out of 100).

H22-ANNChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

H22-QT50Choose it when strength drives the design, or when the part sees heat.

H22-ANN vs H22-QT50: properties

H22-ANNH22-QT50

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

207 GPa30 Msi
212 GPa30.7 Msi

Tensile Strength (Ultimate)

790 MPa115 ksi
1,720 MPa249 ksi

Yield Strength (0.2% offset)

470 MPa68.2 ksi
1,450 MPa210 ksi

Elongation at Break

18%
7%

Reduction in Area

38%
22%

Compressive Strength

500 MPa72.5 ksi
2,000 MPa290 ksi

Shear Strength

480 MPa69.6 ksi
1,050 MPa152 ksi

Fatigue Strength (Endurance Limit)

370 MPa53.7 ksi
700 MPa102 ksi

Fracture Toughness (K_IC)

55 MPa·√m50.1 ksi·√in
25 MPa·√m22.8 ksi·√in

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
10 J7.4 ft·lbf

Hardness, Brinell

212 HB
481 HB

Hardness, Vickers

223 HV
513 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Rockwell B 95 HRB

Physical

Density and transition temperatures.

Same in both: Density 8.45 g/cm³0.31 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,475°C2,687 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

27 W/m·K15.6 BTU/hr·ft·°F
28 W/m·K16.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

500°C932 °F
600°C1,112 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11 µm/m·K6.1 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 3.1 % IACS · Electrical Resistivity 5.5×10⁻⁷ Ω·m21.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

16 / 100
17 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.55 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
8 / 100

Machinability Rating (AISI 1212 = 100 %)

38%
8%

Weldability

30 / 100
18 / 100

Polishability

55 / 100
60 / 100

Same in both: Formability (cold) 15 / 100 · Castability 25 / 100 · Brazeability / Solderability 35 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 75 L/kg9 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleH22

H22-ANN vs H22-QT50 — frequently asked

Is H22-QT50 stronger than H22-ANN?

Yes. H22-QT50 has a typical yield strength of 1,450 MPa (210 ksi) against 470 MPa (68.2 ksi) for H22-ANN — about 3.1 times as much. Tensile strength is 1,720 MPa (249 ksi) vs 790 MPa (115 ksi).

Which condition does FabDigit quote by default, ANN or QT50?

ANN is the default H22 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, H22-ANN or H22-QT50?

H22-ANN. Its machinability rates poor (32/100) against not recommended (8/100) for H22-QT50; for welding the order is H22-ANN first (poor, 30/100) then H22-QT50 (poor, 18/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in H22-ANN and H22-QT50 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.