FabDigitFabDigit

Steel H08A Annealed vs H08A-AW

Steel · H08A temper comparison

H08A Annealed and H08A-AW are two conditions of the same steel grade, H08A: Annealed versus AW (as-welded deposit). The chemistry is identical, so every difference below comes from the condition. H08A-AW is the stronger of the two: yield strength 360 MPa (52.2 ksi) against 210 MPa (30.5 ksi) for H08A Annealed, about 71% more; tensile strength follows at 480 MPa (69.6 ksi) vs 370 MPa (53.7 ksi). In exchange, H08A Annealed is the more ductile: elongation 38% versus 28% for H08A-AW, and H08A-AW is harder (145 HB vs 105 HB).

H08A AnnealedChoose it when the part is bent, formed or impact-loaded.

H08A-AWChoose it when strength drives the design.

H08A Annealed vs H08A-AW: properties

H08A AnnealedH08A-AW

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

370 MPa53.7 ksi
480 MPa69.6 ksi

Yield Strength (0.2% offset)

210 MPa30.5 ksi
360 MPa52.2 ksi

Elongation at Break

38%
28%

Reduction in Area

68%
55%

Shear Strength

230 MPa33.4 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

170 MPa24.7 ksi
200 MPa29 ksi

Charpy V-Notch Impact (RT)

120 J88.5 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

105 HB
145 HB

Hardness, Rockwell B

58 HRB
78 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,500°C2,732 °F · Liquidus Temperature 1,525°C2,777 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

52 W/m·K30 BTU/hr·ft·°F
50 W/m·K28.9 BTU/hr·ft·°F

Min Service Temperature

-40°C-40 °F
-20°C-4 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11 % IACS
10 % IACS

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
52 / 100

Weldability

98 / 100
95 / 100

Formability (cold)

95 / 100
72 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 58% · Brazeability / Solderability 75 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleH08A

H08A Annealed vs H08A-AW — frequently asked

Is H08A-AW stronger than H08A Annealed?

Yes. H08A-AW has a typical yield strength of 360 MPa (52.2 ksi) against 210 MPa (30.5 ksi) for H08A Annealed — about 71% more. Tensile strength is 480 MPa (69.6 ksi) vs 370 MPa (53.7 ksi).

Which condition does FabDigit quote by default, Annealed or AW?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

When should I choose H08A Annealed over H08A-AW?

Pick H08A Annealed when the part is bent, formed or impact-loaded. Pick H08A-AW when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in H08A Annealed and H08A-AW side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.