GX5NiS36-HIP and GX5NiS36-SR are two conditions of the same steel grade, GX5NiS36: HIP (hot isostatic pressed) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. GX5NiS36-HIP is the stronger of the two: tensile strength 450 MPa (65.3 ksi) against 420 MPa (60.9 ksi) for GX5NiS36-SR, about 7% more. GX5NiS36-HIP is the more ductile: elongation 18% versus 12% for GX5NiS36-SR.

GX5NiS36-HIPChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

GX5NiS36-HIP vs GX5NiS36-SR: properties

GX5NiS36-HIPGX5NiS36-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

142 GPa20.6 Msi
140 GPa20.3 Msi

Tensile Strength (Ultimate)

450 MPa65.3 ksi
420 MPa60.9 ksi

Yield Strength (0.2% offset)

210 MPa30.5 ksi
200 MPa29 ksi

Elongation at Break

18%
12%

Reduction in Area

30%
20%

Compressive Strength

460 MPa66.7 ksi
430 MPa62.4 ksi

Shear Strength

320 MPa46.4 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
160 MPa23.2 ksi

Fracture Toughness (K_IC)

75 MPa·√m68.3 ksi·√in
58 MPa·√m52.8 ksi·√in

Charpy V-Notch Impact (RT)

28 J20.7 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

140 HB
135 HB

Hardness, Rockwell B

77 HRB
75 HRB

Hardness, Vickers

147 HV
142 HV

Same in both: Shear Modulus 55 GPa8 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 8.1 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

11.8 W/m·K6.8 BTU/hr·ft·°F
11.5 W/m·K6.6 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 515 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 3 µm/m·K1.7 µin/in·°F · Latent Heat of Fusion 275 J/g118 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -150°C-238 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.2 % IACS
2.1 % IACS

Electrical Resistivity

8.1×10⁻⁷ Ω·m31.9 µΩ·in
8.2×10⁻⁷ Ω·m32.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

33 / 100
30 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

30 / 100
25 / 100

Formability (cold)

14 / 100
10 / 100

Same in both: Machinability 40 / 100 · Machinability Rating (AISI 1212 = 100 %) 35% · Castability 60 / 100 · Brazeability / Solderability 55 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 110 MJ/kg47,292 BTU/lb · Embodied Carbon (primary production) 8.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleGX5NiS36

GX5NiS36-HIP vs GX5NiS36-SR — frequently asked

Is GX5NiS36-HIP stronger than GX5NiS36-SR?

Yes. GX5NiS36-HIP has a typical tensile strength of 450 MPa (65.3 ksi) against 420 MPa (60.9 ksi) for GX5NiS36-SR — about 7% more.

Which condition does FabDigit quote by default, HIP or SR?

SR is the default GX5NiS36 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, GX5NiS36-HIP or GX5NiS36-SR?

GX5NiS36-HIP. Its weldability rates poor (30/100) against poor (25/100) for GX5NiS36-SR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in GX5NiS36-HIP and GX5NiS36-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.