GX10CrMoV9-1 N+T and GX10CrMoV9-1 Q+T are two conditions of the same steel grade, GX10CrMoV9-1: N+T (normalized and tempered) versus Q+T (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. GX10CrMoV9-1 Q+T is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 490 MPa (71.1 ksi) for GX10CrMoV9-1 N+T, about 6% more; tensile strength follows at 700 MPa (102 ksi) vs 660 MPa (95.7 ksi). GX10CrMoV9-1 Q+T is harder — 230 HB against 215 HB for GX10CrMoV9-1 N+T — which matters for wear surfaces and threads.
GX10CrMoV9-1 Q+TChoose it when strength drives the design, or when surface hardness matters.
GX10CrMoV9-1 N+T vs GX10CrMoV9-1 Q+T: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
GX10CrMoV9-1 N+TGX10CrMoV9-1 Q+T
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell C
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 218 GPa31.6 Msi · Shear Modulus 84 GPa12.2 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29 · Compressive Strength 500 MPa72.5 ksi · Shear Strength 400 MPa58 ksi · Fatigue Strength (Endurance Limit) 300 MPa43.5 ksi · Fracture Toughness (K_IC) 110 MPa·√m100 ksi·√in
Physical
Density and transition temperatures.
Same in both: Density 7.77 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,495°C2,723 °F
Thermal
How each material carries heat and how hot it can run.
Same in both: Thermal Conductivity 27 W/m·K15.6 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 600°C1,112 °F · Min Service Temperature -20°C-4 °F
Electrical
Conductivity and insulation.
Same in both: Electrical Resistivity 5.5×10⁻⁷ Ω·m21.7 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.55 V · Corrosion Resistance 32 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Same in both: Machinability Rating (AISI 1212 = 100 %) 45% · Weldability 35 / 100 · Formability (cold) 15 / 100 · Castability 55 / 100 · Brazeability / Solderability 30 / 100 · Polishability 55 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.6 kg CO₂/kg · Embodied Water 70 L/kg8.4 gal/lb · Typical Recycled Content 70%
Strength versus weight
Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
GX10CrMoV9-1 N+T vs GX10CrMoV9-1 Q+T — frequently asked
Is GX10CrMoV9-1 Q+T stronger than GX10CrMoV9-1 N+T?
Yes. GX10CrMoV9-1 Q+T has a typical yield strength of 520 MPa (75.4 ksi) against 490 MPa (71.1 ksi) for GX10CrMoV9-1 N+T — about 6% more. Tensile strength is 700 MPa (102 ksi) vs 660 MPa (95.7 ksi).
Which condition does FabDigit quote by default, N+T or Q+T?
N+T is the default GX10CrMoV9-1 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
When should I choose GX10CrMoV9-1 N+T over GX10CrMoV9-1 Q+T?
Pick GX10CrMoV9-1 Q+T when strength drives the design, or when surface hardness matters.
Ready to make it?
Upload a CAD file and FabDigit prices the part in GX10CrMoV9-1 N+T and GX10CrMoV9-1 Q+T side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.