GE270 +A and GE270 +NT are two conditions of the same steel grade, GE270: +A (annealed) versus +NT (normalized and tempered). The chemistry is identical, so every difference below comes from the condition. GE270 +NT is the stronger of the two: yield strength 305 MPa (44.2 ksi) against 255 MPa (37 ksi) for GE270 +A, about 20% more; tensile strength follows at 525 MPa (76.1 ksi) vs 480 MPa (69.6 ksi). GE270 +NT is harder — 158 HB against 140 HB for GE270 +A — which matters for wear surfaces and threads.

GE270 +NTChoose it when strength drives the design, or when surface hardness matters.

GE270 +A vs GE270 +NT: properties

GE270 +AGE270 +NT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

480 MPa69.6 ksi
525 MPa76.1 ksi

Yield Strength (0.2% offset)

255 MPa37 ksi
305 MPa44.2 ksi

Elongation at Break

23%
22%

Compressive Strength

255 MPa37 ksi
305 MPa44.2 ksi

Shear Strength

295 MPa42.8 ksi
325 MPa47.1 ksi

Fatigue Strength (Endurance Limit)

195 MPa28.3 ksi
235 MPa34.1 ksi

Fracture Toughness (K_IC)

66 MPa·√m60.1 ksi·√in
78 MPa·√m71 ksi·√in

Charpy V-Notch Impact (RT)

28 J20.7 ft·lbf
38 J28 ft·lbf

Hardness, Brinell

140 HB
158 HB

Hardness, Rockwell B

76 HRB
83 HRB

Hardness, Vickers

147 HV
166 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Reduction in Area 40%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

49 W/m·K28.3 BTU/hr·ft·°F
48 W/m·K27.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
425°C797 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.5 % IACS
10 % IACS

Electrical Resistivity

1.65×10⁻⁷ Ω·m6.5 µΩ·in
1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

67 / 100
61 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
64%

Weldability

82 / 100
78 / 100

Formability (cold)

20 / 100
16 / 100

Same in both: Castability 78 / 100 · Brazeability / Solderability 55 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 24 MJ/kg10,318 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 55 L/kg6.6 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleGE270

GE270 +A vs GE270 +NT — frequently asked

Is GE270 +NT stronger than GE270 +A?

Yes. GE270 +NT has a typical yield strength of 305 MPa (44.2 ksi) against 255 MPa (37 ksi) for GE270 +A — about 20% more. Tensile strength is 525 MPa (76.1 ksi) vs 480 MPa (69.6 ksi).

Which condition does FabDigit quote by default, +A or +NT?

+N is the default GE270 condition in the FabDigit quote flow (neither +A nor +NT). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, GE270 +A or GE270 +NT?

GE270 +A, by a small margin. Both rate good for machinability — 67/100 against 61/100 for GE270 +NT.

Ready to make it?

Upload a CAD file and FabDigit prices the part in GE270 +A and GE270 +NT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.