G17Mn5 +N and G17Mn5 +QT are two conditions of the same steel grade, G17Mn5: +N (normalized) versus +QT (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. G17Mn5 +QT is the stronger of the two: yield strength 280 MPa (40.6 ksi) against 255 MPa (37 ksi) for G17Mn5 +N, about 10% more; tensile strength follows at 520 MPa (75.4 ksi) vs 490 MPa (71.1 ksi). G17Mn5 +QT is harder — 155 HB against 145 HB for G17Mn5 +N — which matters for wear surfaces and threads.

G17Mn5 +QTChoose it when strength drives the design, or when surface hardness matters.

G17Mn5 +N vs G17Mn5 +QT: properties

G17Mn5 +NG17Mn5 +QT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

490 MPa71.1 ksi
520 MPa75.4 ksi

Yield Strength (0.2% offset)

255 MPa37 ksi
280 MPa40.6 ksi

Elongation at Break

26%
28%

Compressive Strength

255 MPa37 ksi
280 MPa40.6 ksi

Shear Strength

315 MPa45.7 ksi
330 MPa47.9 ksi

Fatigue Strength (Endurance Limit)

200 MPa29 ksi
215 MPa31.2 ksi

Fracture Toughness (K_IC)

105 MPa·√m95.6 ksi·√in
110 MPa·√m100 ksi·√in

Charpy V-Notch Impact (RT)

70 J51.6 ft·lbf
100 J73.8 ft·lbf

Hardness, Brinell

145 HB
155 HB

Hardness, Rockwell B

78 HRB
82 HRB

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Reduction in Area 45%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,465°C2,669 °F · Liquidus Temperature 1,515°C2,759 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 47 W/m·K27.2 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Resistivity 2×10⁻⁷ Ω·m7.87 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
65%

Formability (cold)

22 / 100
20 / 100

Same in both: Weldability 82 / 100 · Castability 72 / 100 · Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 24 MJ/kg10,318 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleG17Mn5

G17Mn5 +N vs G17Mn5 +QT — frequently asked

Is G17Mn5 +QT stronger than G17Mn5 +N?

Yes. G17Mn5 +QT has a typical yield strength of 280 MPa (40.6 ksi) against 255 MPa (37 ksi) for G17Mn5 +N — about 10% more. Tensile strength is 520 MPa (75.4 ksi) vs 490 MPa (71.1 ksi).

Which condition does FabDigit quote by default, +N or +QT?

+QT is the default G17Mn5 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose G17Mn5 +N over G17Mn5 +QT?

Pick G17Mn5 +QT when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in G17Mn5 +N and G17Mn5 +QT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.