FabDigitFabDigit

Steel G10MnMoV6-3 +A vs G10MnMoV6-3 +QT1

Steel · G10MnMoV6-3 temper comparison

G10MnMoV6-3 +A and G10MnMoV6-3 +QT1 are two conditions of the same steel grade, G10MnMoV6-3: +A (annealed) versus +QT1 (quenched and tempered, strength class 1). The chemistry is identical, so every difference below comes from the condition. G10MnMoV6-3 +QT1 is the stronger of the two: yield strength 460 MPa (66.7 ksi) against 310 MPa (45 ksi) for G10MnMoV6-3 +A, about 48% more; tensile strength follows at 610 MPa (88.5 ksi) vs 500 MPa (72.5 ksi). In exchange, G10MnMoV6-3 +A is the more ductile: elongation 25% versus 20% for G10MnMoV6-3 +QT1, and G10MnMoV6-3 +QT1 is harder (180 HB vs 150 HB). G10MnMoV6-3 +QT1 runs hotter in service (400°C vs 350°C continuous).

G10MnMoV6-3 +AChoose it when the part is bent, formed or impact-loaded.

G10MnMoV6-3 +QT1Choose it when strength drives the design, or when the part sees heat.

G10MnMoV6-3 +A vs G10MnMoV6-3 +QT1: properties

G10MnMoV6-3 +AG10MnMoV6-3 +QT1

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

500 MPa72.5 ksi
610 MPa88.5 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
460 MPa66.7 ksi

Elongation at Break

25%
20%

Reduction in Area

55%
50%

Compressive Strength

310 MPa45 ksi
460 MPa66.7 ksi

Shear Strength

300 MPa43.5 ksi
370 MPa53.7 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
230 MPa33.4 ksi

Fracture Toughness (K_IC)

130 MPa·√m118 ksi·√in
125 MPa·√m114 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

150 HB
180 HB

Hardness, Rockwell C

16 HRC
11 HRC

Hardness, Vickers

157 HV
190 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

45 W/m·K26 BTU/hr·ft·°F
42 W/m·K24.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

350°C662 °F
400°C752 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.8 % IACS
7.5 % IACS

Electrical Resistivity

2.21×10⁻⁷ Ω·m8.7 µΩ·in
2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

66 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
62%

Weldability

80 / 100
75 / 100

Formability (cold)

30 / 100
15 / 100

Same in both: Castability 68 / 100 · Brazeability / Solderability 50 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleG10MnMoV6-3

G10MnMoV6-3 +A vs G10MnMoV6-3 +QT1 — frequently asked

Is G10MnMoV6-3 +QT1 stronger than G10MnMoV6-3 +A?

Yes. G10MnMoV6-3 +QT1 has a typical yield strength of 460 MPa (66.7 ksi) against 310 MPa (45 ksi) for G10MnMoV6-3 +A — about 48% more. Tensile strength is 610 MPa (88.5 ksi) vs 500 MPa (72.5 ksi).

Which condition does FabDigit quote by default, +A or +QT1?

+QT2 is the default G10MnMoV6-3 condition in the FabDigit quote flow (neither +A nor +QT1). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, G10MnMoV6-3 +A or G10MnMoV6-3 +QT1?

G10MnMoV6-3 +A, by a small margin. Both rate good for machinability — 66/100 against 60/100 for G10MnMoV6-3 +QT1; for welding the order is G10MnMoV6-3 +A first (very good, 80/100) then G10MnMoV6-3 +QT1 (very good, 75/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in G10MnMoV6-3 +A and G10MnMoV6-3 +QT1 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.