Steel Fe-Co 50 (unalloyed)-A vs Fe-Co 50 (unalloyed)-HR
Steel · Fe-Co 50 (unalloyed) temper comparison
Fe-Co 50 (unalloyed)-A and Fe-Co 50 (unalloyed)-HR are two conditions of the same steel grade, Fe-Co 50 (unalloyed): A (solution annealed) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. Fe-Co 50 (unalloyed)-HR is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 350 MPa (50.8 ksi) for Fe-Co 50 (unalloyed)-A, about 9% more; tensile strength follows at 560 MPa (81.2 ksi) vs 520 MPa (75.4 ksi). Fe-Co 50 (unalloyed)-HR is the more ductile: elongation 4% versus 2% for Fe-Co 50 (unalloyed)-A, and Fe-Co 50 (unalloyed)-A is harder (300 HB vs 200 HB). On the shop floor, Fe-Co 50 (unalloyed)-HR welds better (30 vs 20 out of 100).
Fe-Co 50 (unalloyed)-HRChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.
Fe-Co 50 (unalloyed)-A vs Fe-Co 50 (unalloyed)-HR: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Fe-Co 50 (unalloyed)-AFe-Co 50 (unalloyed)-HR
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Compressive Strength
Shear Strength
Fatigue Strength (Endurance Limit)
Fracture Toughness (K_IC)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell C
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 168 GPa24.4 Msi · Poisson's Ratio 0.3
Physical
Density and transition temperatures.
Same in both: Density 8.2 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,470°C2,678 °F · Liquidus Temperature 1,500°C2,732 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 9.5 µm/m·K5.3 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Max Service Temperature (continuous) 500°C932 °F · Min Service Temperature -50°C-58 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.55 V · Corrosion Resistance 14 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Machinability 30 / 100 · Castability 30 / 100 · Brazeability / Solderability 55 / 100 · Polishability 60 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 110 MJ/kg47,292 BTU/lb · Embodied Carbon (primary production) 8.5 kg CO₂/kg · Embodied Water 400 L/kg47.9 gal/lb · Typical Recycled Content 25%
Strength versus weight
Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
Fe-Co 50 (unalloyed)-A vs Fe-Co 50 (unalloyed)-HR — frequently asked
Is Fe-Co 50 (unalloyed)-HR stronger than Fe-Co 50 (unalloyed)-A?
Yes. Fe-Co 50 (unalloyed)-HR has a typical yield strength of 380 MPa (55.1 ksi) against 350 MPa (50.8 ksi) for Fe-Co 50 (unalloyed)-A — about 9% more. Tensile strength is 560 MPa (81.2 ksi) vs 520 MPa (75.4 ksi).
Which condition does FabDigit quote by default, A or HR?
CR is the default Fe-Co 50 (unalloyed) condition in the FabDigit quote flow (neither A nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which welds better, Fe-Co 50 (unalloyed)-A or Fe-Co 50 (unalloyed)-HR?
Fe-Co 50 (unalloyed)-HR. Its weldability rates poor (30/100) against poor (20/100) for Fe-Co 50 (unalloyed)-A.
Ready to make it?
Upload a CAD file and FabDigit prices the part in Fe-Co 50 (unalloyed)-A and Fe-Co 50 (unalloyed)-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.