Steel · F1 temper comparison

F1 CD-ANN and F1-N are two conditions of the same steel grade, F1: CD-ANN (cold Drawn Annealed) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. F1 CD-ANN is the stronger of the two: yield strength 600 MPa (87 ksi) against 520 MPa (75.4 ksi) for F1-N, about 15% more. F1 CD-ANN is the more ductile: elongation 12% versus 10% for F1-N, and F1-N is harder (285 HB vs 217 HB). F1-N runs hotter in service (250°C vs 200°C continuous). On the shop floor, F1 CD-ANN machines more easily (52 vs 42 out of 100).

F1 CD-ANNChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

F1-NChoose it when the part sees heat.

F1 CD-ANN vs F1-N: properties

F1 CD-ANNF1-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

780 MPa113 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

600 MPa87 ksi
520 MPa75.4 ksi

Elongation at Break

12%
10%

Reduction in Area

35%
28%

Compressive Strength

610 MPa88.5 ksi
540 MPa78.3 ksi

Shear Strength

490 MPa71.1 ksi
560 MPa81.2 ksi

Fatigue Strength (Endurance Limit)

360 MPa52.2 ksi
405 MPa58.7 ksi

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

217 HB
285 HB

Hardness, Rockwell B

97 HRB
93 HRB

Hardness, Vickers

228 HV
300 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,470°C2,678 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

41 W/m·K23.7 BTU/hr·ft·°F
40 W/m·K23.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
250°C482 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

9.5 % IACS
9 % IACS

Electrical Resistivity

1.8×10⁻⁷ Ω·m7.09 µΩ·in
1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
55%

Formability (cold)

18 / 100
12 / 100

Same in both: Weldability 10 / 100 · Castability 25 / 100 · Brazeability / Solderability 45 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 33 MJ/kg14,187 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleF1

F1 CD-ANN vs F1-N — frequently asked

Is F1 CD-ANN stronger than F1-N?

Yes. F1 CD-ANN has a typical yield strength of 600 MPa (87 ksi) against 520 MPa (75.4 ksi) for F1-N — about 15% more. Tensile strength is 780 MPa (113 ksi) vs 900 MPa (131 ksi).

Which condition does FabDigit quote by default, CD-ANN or N?

ANN is the default F1 condition in the FabDigit quote flow (neither CD-ANN nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, F1 CD-ANN or F1-N?

F1 CD-ANN, by a small margin. Both rate fair for machinability — 52/100 against 42/100 for F1-N.

Ready to make it?

Upload a CAD file and FabDigit prices the part in F1 CD-ANN and F1-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.