FabDigitFabDigit

Steel EN24 Annealed vs EN24-CR

Steel · EN24 temper comparison

EN24 Annealed and EN24-CR are two conditions of the same steel grade, EN24: Annealed versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. EN24-CR is the stronger of the two: yield strength 700 MPa (102 ksi) against 470 MPa (68.2 ksi) for EN24 Annealed, about 49% more; tensile strength follows at 900 MPa (131 ksi) vs 750 MPa (109 ksi). In exchange, EN24 Annealed is the more ductile: elongation 22% versus 9% for EN24-CR, and EN24-CR is harder (265 HB vs 217 HB). EN24 Annealed runs hotter in service (400°C vs 300°C continuous). On the shop floor, EN24 Annealed welds better (fair vs poor).

EN24 AnnealedChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

EN24-CRChoose it when strength drives the design.

EN24 Annealed vs EN24-CR: properties

EN24 AnnealedEN24-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

750 MPa109 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

470 MPa68.2 ksi
700 MPa102 ksi

Elongation at Break

22%
9%

Reduction in Area

50%
40%

Compressive Strength

760 MPa110 ksi
720 MPa104 ksi

Shear Strength

560 MPa81.2 ksi
540 MPa78.3 ksi

Fatigue Strength (Endurance Limit)

350 MPa50.8 ksi
400 MPa58 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
75 MPa·√m68.3 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

217 HB
265 HB

Hardness, Rockwell C

22 HRC
26 HRC

Hardness, Vickers

290 HV
278 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
300°C572 °F

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.8 % IACS · Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 15 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
55%

Weldability

40 / 100
25 / 100

Formability (cold)

45 / 100
25 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 34 MJ/kg14,617 BTU/lb · Embodied Carbon (primary production) 2.3 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleEN24

EN24 Annealed vs EN24-CR — frequently asked

Is EN24-CR stronger than EN24 Annealed?

Yes. EN24-CR has a typical yield strength of 700 MPa (102 ksi) against 470 MPa (68.2 ksi) for EN24 Annealed — about 49% more. Tensile strength is 900 MPa (131 ksi) vs 750 MPa (109 ksi).

Which condition does FabDigit quote by default, Annealed or CR?

HR is the default EN24 condition in the FabDigit quote flow (neither Annealed nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN24 Annealed or EN24-CR?

EN24 Annealed, by a small margin. Both rate good for machinability — 62/100 against 55/100 for EN24-CR; for welding the order is EN24 Annealed first (fair, 40/100) then EN24-CR (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN24 Annealed and EN24-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.