FabDigitFabDigit

Steel E470 +A vs E470 +C

Steel · E470 temper comparison

E470 +A and E470 +C are two conditions of the same steel grade, E470: +A (annealed) versus +C (cold drawn). The chemistry is identical, so every difference below comes from the condition. E470 +C is the stronger of the two: yield strength 580 MPa (84.1 ksi) against 330 MPa (47.9 ksi) for E470 +A, about 76% more; tensile strength follows at 700 MPa (102 ksi) vs 600 MPa (87 ksi). In exchange, E470 +A is the more ductile: elongation 20% versus 10% for E470 +C, and E470 +C is harder (210 HB vs 180 HB).

E470 +AChoose it when the part is bent, formed or impact-loaded.

E470 +CChoose it when strength drives the design.

E470 +A vs E470 +C: properties

E470 +AE470 +C

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

600 MPa87 ksi
700 MPa102 ksi

Yield Strength (0.2% offset)

330 MPa47.9 ksi
580 MPa84.1 ksi

Elongation at Break

20%
10%

Reduction in Area

45%
35%

Fatigue Strength (Endurance Limit)

270 MPa39.2 ksi
320 MPa46.4 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
15 J11.1 ft·lbf

Hardness, Brinell

180 HB
210 HB

Hardness, Rockwell B

88 HRB
96 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 580 MPa84.1 ksi · Shear Strength 430 MPa62.4 ksi · Fracture Toughness (K_IC) 50 MPa·√m45.5 ksi·√in · Hardness, Rockwell C 18 HRC · Hardness, Vickers 220 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9.6 % IACS · Electrical Resistivity 1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
58%

Formability (cold)

45 / 100
25 / 100

Same in both: Weldability 32 / 100 · Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleE470

E470 +A vs E470 +C — frequently asked

Is E470 +C stronger than E470 +A?

Yes. E470 +C has a typical yield strength of 580 MPa (84.1 ksi) against 330 MPa (47.9 ksi) for E470 +A — about 76% more. Tensile strength is 700 MPa (102 ksi) vs 600 MPa (87 ksi).

Which condition does FabDigit quote by default, +A or +C?

+C is the default E470 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, E470 +A or E470 +C?

E470 +A, by a small margin. Both rate good for machinability — 62/100 against 55/100 for E470 +C.

Ready to make it?

Upload a CAD file and FabDigit prices the part in E470 +A and E470 +C side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.