FabDigitFabDigit

Steel E315 +C vs E315 +SR

Steel · E315 temper comparison

E315 +C and E315 +SR are two conditions of the same steel grade, E315: +C (cold drawn) versus +SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. E315 +C is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 440 MPa (63.8 ksi) for E315 +SR, about 18% more; tensile strength follows at 620 MPa (89.9 ksi) vs 550 MPa (79.8 ksi). In exchange, E315 +SR is the more ductile: elongation 13% versus 8% for E315 +C, and E315 +C is harder (190 HB vs 175 HB). E315 +C runs hotter in service (350°C vs 300°C continuous).

E315 +CChoose it when strength drives the design, or when the part sees heat.

E315 +SRChoose it when the part is bent, formed or impact-loaded.

E315 +C vs E315 +SR: properties

E315 +CE315 +SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

520 MPa75.4 ksi
440 MPa63.8 ksi

Elongation at Break

8%
13%

Reduction in Area

55%
45%

Compressive Strength

350 MPa50.8 ksi
440 MPa63.8 ksi

Shear Strength

320 MPa46.4 ksi
340 MPa49.3 ksi

Fatigue Strength (Endurance Limit)

280 MPa40.6 ksi
260 MPa37.7 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
85 MPa·√m77.4 ksi·√in

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
28 J20.7 ft·lbf

Hardness, Brinell

190 HB
175 HB

Hardness, Rockwell B

91 HRB
87 HRB

Hardness, Vickers

200 HV
184 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
300°C572 °F

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
67 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
70%

Weldability

80 / 100
85 / 100

Formability (cold)

40 / 100
52 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 75 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleE315

E315 +C vs E315 +SR — frequently asked

Is E315 +C stronger than E315 +SR?

Yes. E315 +C has a typical yield strength of 520 MPa (75.4 ksi) against 440 MPa (63.8 ksi) for E315 +SR — about 18% more. Tensile strength is 620 MPa (89.9 ksi) vs 550 MPa (79.8 ksi).

Which condition does FabDigit quote by default, +C or +SR?

+N is the default E315 condition in the FabDigit quote flow (neither +C nor +SR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, E315 +C or E315 +SR?

E315 +SR, by a small margin. Both rate good for machinability — 67/100 against 62/100 for E315 +C; for welding the order is E315 +SR first (excellent, 85/100) then E315 +C (very good, 80/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in E315 +C and E315 +SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.