FabDigitFabDigit

Steel E315 +AR vs E315 +C

Steel · E315 temper comparison

E315 +AR and E315 +C are two conditions of the same steel grade, E315: +AR (hot rolled) versus +C (cold drawn). The chemistry is identical, so every difference below comes from the condition. E315 +C is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 330 MPa (47.9 ksi) for E315 +AR, about 58% more; tensile strength follows at 620 MPa (89.9 ksi) vs 510 MPa (74 ksi). In exchange, E315 +AR is the more ductile: elongation 22% versus 8% for E315 +C, and E315 +C is harder (190 HB vs 150 HB).

E315 +ARChoose it when the part is bent, formed or impact-loaded.

E315 +CChoose it when strength drives the design.

E315 +AR vs E315 +C: properties

E315 +ARE315 +C

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

510 MPa74 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

330 MPa47.9 ksi
520 MPa75.4 ksi

Elongation at Break

22%
8%

Compressive Strength

330 MPa47.9 ksi
350 MPa50.8 ksi

Shear Strength

315 MPa45.7 ksi
320 MPa46.4 ksi

Fatigue Strength (Endurance Limit)

235 MPa34.1 ksi
280 MPa40.6 ksi

Fracture Toughness (K_IC)

95 MPa·√m86.5 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

38 J28 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

150 HB
190 HB

Hardness, Rockwell B

80 HRB
91 HRB

Hardness, Vickers

158 HV
200 HV

Same in both: Elastic (Young's) Modulus 210 GPa30.5 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Reduction in Area 55%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,500°C2,732 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
72%

Weldability

88 / 100
80 / 100

Formability (cold)

66 / 100
40 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 75 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleE315

E315 +AR vs E315 +C — frequently asked

Is E315 +C stronger than E315 +AR?

Yes. E315 +C has a typical yield strength of 520 MPa (75.4 ksi) against 330 MPa (47.9 ksi) for E315 +AR — about 58% more. Tensile strength is 620 MPa (89.9 ksi) vs 510 MPa (74 ksi).

Which condition does FabDigit quote by default, +AR or +C?

+N is the default E315 condition in the FabDigit quote flow (neither +AR nor +C). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, E315 +AR or E315 +C?

E315 +AR. Its weldability rates excellent (88/100) against very good (80/100) for E315 +C.

Ready to make it?

Upload a CAD file and FabDigit prices the part in E315 +AR and E315 +C side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.