FabDigitFabDigit

Steel CRS-CD vs CRS-HR

Steel · CRS temper comparison

CRS-CD and CRS-HR are two conditions of the same steel grade, CRS: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. CRS-CD is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 250 MPa (36.3 ksi) for CRS-HR, about 48% more; tensile strength follows at 440 MPa (63.8 ksi) vs 365 MPa (52.9 ksi). In exchange, CRS-HR is the more ductile: elongation 32% versus 15% for CRS-CD, and CRS-CD is harder (130 HB vs 110 HB). On the shop floor, CRS-CD machines more easily (good vs fair).

CRS-CDChoose it when strength drives the design, or when the part is machined in volume.

CRS-HRChoose it when the part is bent, formed or impact-loaded.

CRS-CD vs CRS-HR: properties

CRS-CDCRS-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

440 MPa63.8 ksi
365 MPa52.9 ksi

Yield Strength (0.2% offset)

370 MPa53.7 ksi
250 MPa36.3 ksi

Elongation at Break

15%
32%

Reduction in Area

45%
65%

Shear Strength

275 MPa39.9 ksi
230 MPa33.4 ksi

Fatigue Strength (Endurance Limit)

210 MPa30.5 ksi
180 MPa26.1 ksi

Hardness, Brinell

130 HB
110 HB

Hardness, Rockwell B

72 HRB
62 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 220 MPa31.9 ksi · Fracture Toughness (K_IC) 120 MPa·√m109 ksi·√in · Charpy V-Notch Impact (RT) 90 J66.4 ft·lbf · Hardness, Vickers 100 HV

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,528°C2,782 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 52 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.2 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 272 J/g117 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 12 % IACS · Electrical Resistivity 1.43×10⁻⁷ Ω·m5.63 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
52 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
50%

Weldability

92 / 100
95 / 100

Formability (cold)

55 / 100
78 / 100

Same in both: Brazeability / Solderability 75 / 100 · Polishability 35 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 50 L/kg6 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleCRS

CRS-CD vs CRS-HR — frequently asked

Is CRS-CD stronger than CRS-HR?

Yes. CRS-CD has a typical yield strength of 370 MPa (53.7 ksi) against 250 MPa (36.3 ksi) for CRS-HR — about 48% more. Tensile strength is 440 MPa (63.8 ksi) vs 365 MPa (52.9 ksi).

Which condition does FabDigit quote by default, CD or HR?

HR is the default CRS condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, CRS-CD or CRS-HR?

CRS-CD. Its machinability rates good (68/100) against fair (52/100) for CRS-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CRS-CD and CRS-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.