C2C +A and C2C +U are two conditions of the same steel grade, C2C: +A (annealed) versus +U (hot rolled). The chemistry is identical, so every difference below comes from the condition. C2C +U is the stronger of the two: yield strength 210 MPa (30.5 ksi) against 185 MPa (26.8 ksi) for C2C +A, about 14% more; tensile strength follows at 320 MPa (46.4 ksi) vs 300 MPa (43.5 ksi). C2C +U is harder — 95 HB against 90 HB for C2C +A — which matters for wear surfaces and threads.

C2C +UChoose it when strength drives the design, or when surface hardness matters.

C2C +A vs C2C +U: properties

C2C +AC2C +U

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

300 MPa43.5 ksi
320 MPa46.4 ksi

Yield Strength (0.2% offset)

185 MPa26.8 ksi
210 MPa30.5 ksi

Elongation at Break

43%
40%

Reduction in Area

75%
72%

Compressive Strength

340 MPa49.3 ksi
210 MPa30.5 ksi

Shear Strength

195 MPa28.3 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

145 MPa21 ksi
155 MPa22.5 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
110 J81.1 ft·lbf

Hardness, Brinell

90 HB
95 HB

Hardness, Rockwell B

50 HRB
55 HRB

Hardness, Vickers

95 HV
100 HV

Same in both: Elastic (Young's) Modulus 207 GPa30 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Fracture Toughness (K_IC) 130 MPa·√m118 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,500°C2,732 °F · Liquidus Temperature 1,535°C2,795 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 60 W/m·K34.7 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 12 % IACS · Electrical Resistivity 1.45×10⁻⁷ Ω·m5.71 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

52%
48%

Formability (cold)

100 / 100
98 / 100

Same in both: Weldability 96 / 100 · Brazeability / Solderability 75 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 40 L/kg4.8 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleC2C

C2C +A vs C2C +U — frequently asked

Is C2C +U stronger than C2C +A?

Yes. C2C +U has a typical yield strength of 210 MPa (30.5 ksi) against 185 MPa (26.8 ksi) for C2C +A — about 14% more. Tensile strength is 320 MPa (46.4 ksi) vs 300 MPa (43.5 ksi).

Which condition does FabDigit quote by default, +A or +U?

+U+C is the default C2C condition in the FabDigit quote flow (neither +A nor +U). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C2C +A over C2C +U?

Pick C2C +U when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C2C +A and C2C +U side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.