FabDigitFabDigit

Steel C20C +AC vs C20C +N

Steel · C20C temper comparison

C20C +AC and C20C +N are two conditions of the same steel grade, C20C: +AC (spheroidize annealed) versus +N (normalized). The chemistry is identical, so every difference below comes from the condition. C20C +N is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 250 MPa (36.3 ksi) for C20C +AC, about 20% more; tensile strength follows at 440 MPa (63.8 ksi) vs 400 MPa (58 ksi). In exchange, C20C +AC is the more ductile: elongation 33% versus 28% for C20C +N, and C20C +N is harder (126 HB vs 112 HB).

C20C +ACChoose it when the part is bent, formed or impact-loaded.

C20C +NChoose it when strength drives the design.

C20C +AC vs C20C +N: properties

C20C +ACC20C +N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
440 MPa63.8 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
300 MPa43.5 ksi

Elongation at Break

33%
28%

Reduction in Area

68%
62%

Fatigue Strength (Endurance Limit)

195 MPa28.3 ksi
220 MPa31.9 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
95 J70.1 ft·lbf

Hardness, Brinell

112 HB
126 HB

Hardness, Rockwell B

62 HRB
71 HRB

Hardness, Vickers

118 HV
138 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 390 MPa56.6 ksi · Shear Strength 330 MPa47.9 ksi · Fracture Toughness (K_IC) 105 MPa·√m95.6 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,460°C2,660 °F · Liquidus Temperature 1,518°C2,764 °F

Thermal

How each material carries heat and how hot it can run.

Min Service Temperature

-20°C-4 °F
-40°C-40 °F

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 350°C662 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

53 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

58%
62%

Formability (cold)

95 / 100
80 / 100

Same in both: Weldability 95 / 100 · Brazeability / Solderability 75 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleC20C

C20C +AC vs C20C +N — frequently asked

Is C20C +N stronger than C20C +AC?

Yes. C20C +N has a typical yield strength of 300 MPa (43.5 ksi) against 250 MPa (36.3 ksi) for C20C +AC — about 20% more. Tensile strength is 440 MPa (63.8 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, +AC or +N?

+U+C is the default C20C condition in the FabDigit quote flow (neither +AC nor +N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C20C +AC or C20C +N?

C20C +N. Its machinability rates good (60/100) against fair (53/100) for C20C +AC.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C20C +AC and C20C +N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.