FabDigitFabDigit

Steel A842 Grade 450 AS-CAST vs A842 Grade 450-IH

Steel · A842 Grade 450 temper comparison

A842 Grade 450 AS-CAST and A842 Grade 450-IH are two conditions of the same steel grade, A842 Grade 450: AS-CAST versus IH (induction hardened). The chemistry is identical, so every difference below comes from the condition. Both yield at about 350 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (AS-CAST versus induction hardened). A842 Grade 450 AS-CAST is the more ductile: elongation 1.5% versus 1.2% for A842 Grade 450-IH, and A842 Grade 450-IH is harder (52 HRC vs 22 HRC). A842 Grade 450 AS-CAST runs hotter in service (400°C vs 250°C continuous). On the shop floor, A842 Grade 450 AS-CAST machines more easily (fair vs not recommended) and A842 Grade 450 AS-CAST welds better (poor vs not recommended).

A842 Grade 450 AS-CASTChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

A842 Grade 450 AS-CAST vs A842 Grade 450-IH: properties

A842 Grade 450 AS-CASTA842 Grade 450-IH

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elongation at Break

1.5%
1.2%

Fatigue Strength (Endurance Limit)

205 MPa29.7 ksi
260 MPa37.7 ksi

Fracture Toughness (K_IC)

25 MPa·√m22.8 ksi·√in
24 MPa·√m21.8 ksi·√in

Charpy V-Notch Impact (RT)

3 J1.8 ft·lbf
2 J1.5 ft·lbf

Hardness, Rockwell C

22 HRC
52 HRC

Hardness, Vickers

250 HV
550 HV

Same in both: Elastic (Young's) Modulus 150 GPa21.8 Msi · Shear Modulus 60 GPa8.7 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.26 · Tensile Strength (Ultimate) 490 MPa71.1 ksi · Yield Strength (0.2% offset) 350 MPa50.8 ksi · Compressive Strength 950 MPa138 ksi · Shear Strength 430 MPa62.4 ksi · Hardness, Brinell 240 HB · Hardness, Rockwell B 99 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.15 g/cm³0.26 lb/in³ · Melting Point (Solidus) 1,150°C2,102 °F · Liquidus Temperature 1,175°C2,147 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
250°C482 °F

Same in both: Thermal Conductivity 36 W/m·K20.8 BTU/hr·ft·°F · Specific Heat Capacity 465 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 220 J/g94.6 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 16 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
12 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
15%

Weldability

25 / 100
10 / 100

Formability (cold)

3 / 100
1 / 100

Same in both: Castability 62 / 100 · Brazeability / Solderability 40 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 22 MJ/kg9,458 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 30 L/kg3.6 gal/lb · Typical Recycled Content 90%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA842 Grade 450

A842 Grade 450 AS-CAST vs A842 Grade 450-IH — frequently asked

What is the difference between A842 Grade 450 AS-CAST and A842 Grade 450-IH?

A842 Grade 450 AS-CAST and A842 Grade 450-IH are two conditions of the same steel grade, A842 Grade 450: AS-CAST versus IH (induction hardened). The chemistry is identical, so every difference below comes from the condition. Both yield at about 350 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (AS-CAST versus induction hardened).

Which condition does FabDigit quote by default, AS-CAST or IH?

AS-CAST is the default A842 Grade 450 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, A842 Grade 450 AS-CAST or A842 Grade 450-IH?

A842 Grade 450 AS-CAST. Its machinability rates fair (35/100) against not recommended (12/100) for A842 Grade 450-IH; for welding the order is A842 Grade 450 AS-CAST first (poor, 25/100) then A842 Grade 450-IH (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in A842 Grade 450 AS-CAST and A842 Grade 450-IH side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.