FabDigitFabDigit

Steel A656 vs Q355C

Steel · grade comparison

Steel A656 and Q355C are both steel grades, both structural steel. A656 is the stronger of the two: yield strength 580 MPa (84.1 ksi) against 380 MPa (55.1 ksi) for Q355C, about 53% more; tensile strength follows at 660 MPa (95.7 ksi) vs 520 MPa (75.4 ksi). In exchange, Q355C is the more ductile: elongation 26% versus 16% for A656, and A656 is harder (215 HB vs 150 HB). Q355C runs hotter in service (400°C vs 350°C continuous). On the shop floor, Q355C machines more easily (good vs fair) and Q355C welds better (excellent vs very good).

A656Choose it when strength drives the design.

Q355CChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

A656 vs Q355C: properties

A656Q355C

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
206 GPa29.9 Msi

Poisson's Ratio

0.29
0.3

Tensile Strength (Ultimate)

660 MPa95.7 ksi
520 MPa75.4 ksi

Yield Strength (0.2% offset)

580 MPa84.1 ksi
380 MPa55.1 ksi

Elongation at Break

16%
26%

Compressive Strength

580 MPa84.1 ksi
380 MPa55.1 ksi

Shear Strength

420 MPa60.9 ksi
340 MPa49.3 ksi

Fatigue Strength (Endurance Limit)

290 MPa42.1 ksi
240 MPa34.8 ksi

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
70 J51.6 ft·lbf

Hardness, Brinell

215 HB
150 HB

Hardness, Rockwell B

96 HRB
80 HRB

Hardness, Rockwell C

18 HRC
—

Hardness, Vickers

225 HV
158 HV

Same in both: Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Reduction in Area 50% · Fracture Toughness (K_IC) 100 MPa·√m91 ksi·√in

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,425°C2,597 °F
1,500°C2,732 °F

Liquidus Temperature

1,510°C2,750 °F
1,520°C2,768 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

46 W/m·K26.6 BTU/hr·ft·°F
45 W/m·K26 BTU/hr·ft·°F

Specific Heat Capacity

480 J/kg·K0.11 BTU/lb·°F
470 J/kg·K0.11 BTU/lb·°F

Max Service Temperature (continuous)

350°C662 °F
400°C752 °F

Min Service Temperature

-40°C-40 °F
0°C32 °F

Same in both: Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

9 % IACS
8.2 % IACS

Electrical Resistivity

1.9×10⁻⁷ Ω·m7.48 µΩ·in
2.1×10⁻⁷ Ω·m8.27 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
68%

Weldability

75 / 100
85 / 100

Formability (cold)

65 / 100
70 / 100

Brazeability / Solderability

45 / 100
55 / 100

Polishability

45 / 100
40 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

25 MJ/kg10,748 BTU/lb
24 MJ/kg10,318 BTU/lb

Embodied Carbon (primary production)

2 kg CO₂/kg
1.9 kg CO₂/kg

Embodied Water

40 L/kg4.8 gal/lb
45 L/kg5.4 gal/lb

Typical Recycled Content

30%
25%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

84 kN·m/kg
66 kN·m/kg

Specific Stiffness (E / density)

25.5 MN·m/kg
26.2 MN·m/kg

Modulus of Resilience

841 kJ/m³
350 kJ/m³

Thermal Shock Resistance Index

13
9

Same in both: Thermal Diffusivity 12.2 mm²/s

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA656Q355C

Manufacturing and finishing

CapabilityA656Q355C
Default conditionHRHR
Relative cost$ Budget$ Budget
Min. machined wall0.8 mm0.8 mm
Best machined surfaceRa 1.6 µmRa 1.6 µm

Both are offered for CNC machining and Sheet metal. Both take the same 38 finishes: AlCrN, AlTiN, Black Oxide, CVD Al2O3, CVD TiCN, CVD TiN, Cerakote, Chrome Plating, Copper Plating, CrN, DLC, E-Coating and 26 more.

A656 vs Q355C — frequently asked

Is A656 stronger than Q355C?

Yes. A656 has a typical yield strength of 580 MPa (84.1 ksi) against 380 MPa (55.1 ksi) for Q355C — about 53% more. Tensile strength is 660 MPa (95.7 ksi) vs 520 MPa (75.4 ksi).

Which is cheaper, A656 or Q355C?

Both sit in the same relative cost tier ($, budget); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, A656 or Q355C?

Q355C. Its machinability rates good (60/100) against fair (50/100) for A656; for welding the order is Q355C first (excellent, 85/100) then A656 (very good, 75/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in A656 and Q355C side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.