A653-A60 and A653-HR are two conditions of the same steel grade, A653: A60 versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. A653-HR is the stronger of the two: yield strength 260 MPa (37.7 ksi) against 235 MPa (34.1 ksi) for A653-A60, about 11% more; tensile strength follows at 360 MPa (52.2 ksi) vs 330 MPa (47.9 ksi). In exchange, A653-A60 is the more ductile: elongation 36% versus 32% for A653-HR, and A653-HR is harder (110 HB vs 100 HB). A653-A60 runs hotter in service (230°C vs 200°C continuous). On the shop floor, A653-A60 welds better (82 vs 72 out of 100).

A653-A60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

A653-HRChoose it when strength drives the design.

A653-A60 vs A653-HR: properties

A653-A60A653-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

330 MPa47.9 ksi
360 MPa52.2 ksi

Yield Strength (0.2% offset)

235 MPa34.1 ksi
260 MPa37.7 ksi

Elongation at Break

36%
32%

Reduction in Area

65%
55%

Compressive Strength

235 MPa34.1 ksi
260 MPa37.7 ksi

Shear Strength

215 MPa31.2 ksi
235 MPa34.1 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
170 MPa24.7 ksi

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

100 HB
110 HB

Hardness, Rockwell B

55 HRB
62 HRB

Hardness, Vickers

105 HV
115 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

230°C446 °F
200°C392 °F

Same in both: Thermal Conductivity 52 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.5 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

28 / 100
38 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -1.02 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
66%

Weldability

82 / 100
72 / 100

Formability (cold)

80 / 100
82 / 100

Polishability

30 / 100
25 / 100

Same in both: Brazeability / Solderability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 30 MJ/kg12,898 BTU/lb · Embodied Carbon (primary production) 2.5 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA653

A653-A60 vs A653-HR — frequently asked

Is A653-HR stronger than A653-A60?

Yes. A653-HR has a typical yield strength of 260 MPa (37.7 ksi) against 235 MPa (34.1 ksi) for A653-A60 — about 11% more. Tensile strength is 360 MPa (52.2 ksi) vs 330 MPa (47.9 ksi).

Which condition does FabDigit quote by default, A60 or HR?

HR is the default A653 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, A653-A60 or A653-HR?

A653-A60. Its weldability rates very good (82/100) against very good (72/100) for A653-HR.