A516 Gr 70 Annealed and A516 Gr 70-HR are two conditions of the same steel grade, A516 Gr 70: Annealed versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. A516 Gr 70-HR is the stronger of the two: yield strength 320 MPa (46.4 ksi) against 290 MPa (42.1 ksi) for A516 Gr 70 Annealed, about 10% more; tensile strength follows at 550 MPa (79.8 ksi) vs 505 MPa (73.2 ksi). In exchange, A516 Gr 70 Annealed is the more ductile: elongation 28% versus 25% for A516 Gr 70-HR, and A516 Gr 70-HR is harder (150 HB vs 140 HB).

A516 Gr 70 AnnealedChoose it when the part is bent, formed or impact-loaded.

A516 Gr 70-HRChoose it when strength drives the design.

A516 Gr 70 Annealed vs A516 Gr 70-HR: properties

A516 Gr 70 AnnealedA516 Gr 70-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

505 MPa73.2 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

290 MPa42.1 ksi
320 MPa46.4 ksi

Elongation at Break

28%
25%

Reduction in Area

55%
50%

Fatigue Strength (Endurance Limit)

225 MPa32.6 ksi
240 MPa34.8 ksi

Charpy V-Notch Impact (RT)

50 J36.9 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

140 HB
150 HB

Hardness, Rockwell B

76 HRB
80 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 320 MPa46.4 ksi · Shear Strength 350 MPa50.8 ksi · Fracture Toughness (K_IC) 110 MPa·√m100 ksi·√in · Hardness, Vickers 158 HV

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 52 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 247 J/g106 BTU/lb · Max Service Temperature (continuous) 425°C797 °F · Min Service Temperature -29°C-20 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

66 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
68%

Formability (cold)

82 / 100
75 / 100

Same in both: Weldability 90 / 100 · Brazeability / Solderability 70 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA516 Gr 70

A516 Gr 70 Annealed vs A516 Gr 70-HR — frequently asked

Is A516 Gr 70-HR stronger than A516 Gr 70 Annealed?

Yes. A516 Gr 70-HR has a typical yield strength of 320 MPa (46.4 ksi) against 290 MPa (42.1 ksi) for A516 Gr 70 Annealed — about 10% more. Tensile strength is 550 MPa (79.8 ksi) vs 505 MPa (73.2 ksi).

Which condition does FabDigit quote by default, Annealed or HR?

HR is the default A516 Gr 70 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose A516 Gr 70 Annealed over A516 Gr 70-HR?

Pick A516 Gr 70 Annealed when the part is bent, formed or impact-loaded. Pick A516 Gr 70-HR when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A516 Gr 70 Annealed and A516 Gr 70-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.